Action When Data Transfer Fails - Konica Minolta bizhub C280 Service Manual

For pki card system
Hide thumbs Also See for bizhub C280:
Table of Contents

Advertisement

Security Function Ver. 1.02 Jul. 2010
13. Call the Service Mode to the screen.
14. Select [Firmware Version].
15. Make sure if the version of firmware is updated.
10.2.3

Action when data transfer fails

• If "NG" appears on the control panel, indicating that rewriting has been unsuccessful (in
which case the Start key lights up red), take the following steps.
1. Perform the data rewriting procedure again.
2. If the procedure is abnormally terminated, change the USB memory for a new one and
try another rewriting sequence.
3. If the procedure is still abnormally terminated, change the board that has caused "NG"
and carry out data rewriting procedure.
F/W to be updated
MFP CONTROLLER
SCANNER
PRINTER
FAX BOARD CONTROLLER1 Fax board (Main)
FAX BOARD CONTROLLER2 Fax board (Sub)
ADF (DF-M)
FINISHER
RU
SD
DSC1
DSC2
Appropriate board
MFP board (MFPB)
MFP board (MFPB)
Printer control board (PRCB)
DF control board (DFCB)
FNS control board (FSCB)
Transfer control board (TRCB)
SD drive board (SDDB)
DSC board
Not used
10. Firmware rewriting
A0EDS1E042DA
Remark
Only when the FK-502 is mounted
Only when the FK-502 is mounted
Only when the FS-527/529 is
mounted
Only when the SD-509 is mounted
Only when the SC-507 is mounted