Time-Out Timer (Tot); Locking The Transmit Band; Simultaneous In-Band Reception - Kenwood TM-732A Instruction Manual

144/440/430 mhz fm dual bander
Hide thumbs Also See for TM-732A:
Table of Contents

Advertisement

HBADVANCED TRANSMIT FUNCTIONS
1. Time-Out Timer (TOT)
A Time-out-timer function has been provided to protect
the radio from accidentally locking the unit in transmit for
long time periods. This function allows you to specify
the maximum transmit key down time.
Options include; 3, 5, 10, 20, 30, or no time limit.
(The factory default is no time limit.)
© Function selection
1. Turn the power switch OFF.
2. Press and hold the LOW key and turn the power ON.
The current selection will appear in the display.
®
3. Turn the tuning control to select the maximum key
down time. TOT will appear in the display for all
selections except OFF.
4. Press any key to return to the normal frequency
display.
If you should activate the Time-out-timer function a
beep will sound from the speaker and the transceiver
will return to the receive mode. You will need to press
the PTT switch to transmit again.
2. Locking the Transmit Band
©
Function selection
1. Press the F key momentarily.
Reception.
It is possible to select either frequency as the transmit
frequency during simultaneous in-band reception
(receiving on two different frequencies in the same
band). To select the desired transmit frequency simply
press the BAND Sel key that corresponds with the
desired transmit frequency.
Note:
Reception on the other frequency will not be possible
while the PTT key is depressed.
34