13. SERVICE MODE
13.4.16

MAIN SCAN SCALE - MAIN SCAN PAGE

A. Use
• Prints the test pattern used for the main scan adjustment.
B. Procedure
1. Call the Service Mode to the display.
2. Select [ADJUST]
Select key.
3. Select [PRINT], and press the Select key.
4. The test pattern is output.
13.4.17

MAIN SCAN SCALE - SCAN ADJUST VALUE

A. Use
• Adjusts magnification in the main scan direction.
• Use when replacing the PH unit.
• This adjustment is necessary when the adjustment values are cleared due to the
replacement of the EEPROM on the print control board or other reasons.
B. Procedure
1. Select [ADJUST]
tern.
10
9
8
7
6
A
5
4
3
2
1
0
146
[MAIN SCAN SCALE]
[MAIN SCAN SCALE]
Field Service Ver. 1.1 May 2011
[MAIN SCAN PAGE], and press the
[MAIN SCAN PAGE] to print the test pat-
10
9
8
7
6
B
5
4
3
2
1
0