Things to know – connecting the power cords
Observe the following:
Bosch Sicherheitssysteme GmbH
Installing the drive trays for the E2700 controller-drive tray configurations | en
Lower the drive straight down, and then rotate the drive handle down until the drive
snaps into place under the drive release lever as shown in the following figure.
2
1
1 - Drive release lever
2 - Drive handle
Install the other drives in rows from left to right until the drive drawer contains at least
four drives in the front row of each drawer.
Push the drive drawer all the way back into the drive tray, closing the levers on each side
of the drive drawer.
Note: Risk of equipment malfunction – Make sure you push both levers to each side so
the drive drawer is completely closed. The drive drawer must be completely closed to
prevent excess airflow, which has the potential to damage the drives.
Continue onto the next drive drawer, repeating step 1 through step 7 for each drive
drawer in the configuration.
For each AC power connector on the drive tray, make sure that you use a separate power
source in the cabinet. Connecting to independent power sources maintains power
redundancy.
To ensure proper cooling and assure availability, the drive tray always uses two power
supplies.
You can use the power cords shipped with the drive tray with typical outlets used in the
destination country, such as a wall receptacle or an uninterrupted power supply (UPS).
These power cords, however, are not intended for use in most EIA-compliant cabinets.