Automatic dispensing

Automatic dispensing via an external
dispensing system can be activated
Factory default: Off
Adjustment value dispensing 1–6
To address the tolerances that occur
in the pump system over time, the dis-
pensing amount (ml/min) for the
pumps can be corrected.
The calibration value can be reduced by
3 increments or increased by 3 incre-
ments.
The calibration value is increased or re-
duced by 1, 2 or 3 times the adjustment
value based on the selected incremen-
tal setting.
The calibration value and the adjust-
ment value must be added to the data
for the dispenser pumps by Miele Cus-
tomer Service.
Supervisor level

Peak load signal

External hardware is connected via the
Miele XCI Box.
The peak-load negotiation function
enables the washing machine to be
connected to an energy management
system. When a signal is registered,
the washing machine's heater is
switched off for a short period.
The washing machine may only be op-
erated with a peak-load system if this
system is connected to the washing
machine via the Miele XCI Box.
- No function (factory default)
- Peak load with 230 V
- Peak load with 0 V
- Com module

Peak load prevention

The peak-load negotiation function
can be deactivated with disinfection
programs. When a signal is registered,
the washing machine's heater is not
switched off.
Factory default: Off