Supervisor level
External program lock
The control unit has an option to block
programs. Programs are blocked by
an external system via the COM inter-
face.
Factory default: off
Payment system lock
To avoid tampering, a program lock
can be set up in program operation. If
the lock is applied, the program is in-
terrupted and payment credit is lost as
soon as the door is opened.
The time for the lock can be adjusted to
prevent laundry being added.
- Off
- As soon as the program starts
- 1 minute after the start of the pro-
gram
- 2 minutes after the start of the pro-
gram
- 3 minutes after the start of the pro-
gram (factory default)
- 4 minutes after the start of the pro-
gram
- 5 minutes after the start of the pro-
gram
102
Program abort
A program that is currently running
can be interrupted even if it is locked.
-
On, without code
-
On, with code
(Code from
Expert code
-
Do not cancel
Feedback sig. to pay system
Setting the feedback signal for the
coin box.
- Factory default: Off
- End of program
The feedback signal is sent at the
end of the program.
- Release of the start button
The feedback signal is sent when the
start button is released.
- Start and end of program
The feedback signal is sent at the
start and end of the program.
- Program running
The feedback signal is sent con-
stantly between the start and end of
the program.
(factory default)
setting)