VESA Standardized Mounting
The rear plate has 4 threaded holes for attaching the microphone to a VESA mounting device. The mounting holes follow the
VESA MIS-D standard:
•
Screw specification: M4 thread (hole depth = 9.15 mm)
•
Hole spacing: 100 mm square
The VESA mounting holes work with Shure's
Suspending from the Ceiling
Suspend the microphone using your own equipment, or with Shure's
To mount using your own equipment, you will need:
•
Braided metal cable or high-strength wire
•
Hardware to attach cable to ceiling
1.
Attach the mounting cables to the 12 mm diameter eyelet screws on the microphone.
2.
Attach the cables to the ceiling using the appropriate hardware.
Install on a Ceiling with the A900-CM
Attach array microphones to the ceiling with the A900-CM mounting kit.
Refer to the
A900-CM user guide
A900-PM
and
A900-PM-3/8IN
to learn how to install on other ceiling materials.
accessories to mount the microphone on a pole.
A900-GM kit
(includes mounting cables and hooks).