5. Protection Pass mode
5.1.
Specifications
•
Turn the power on with Protection disabled.
Except for disabling the Protection detection, this operation is the same as the normal power on.
5.2.
Operation
1.
Press the "Power Operation ( X )" button while pressing
"SOUND MODE" and "DISPLAY" and "STATUS" buttons on the set to turn the power on.
2.
The POWER ON sequence starts. The Protection detection is disabled.
P r o t e c t
FLD
P a s s
This is displayed for 5 seconds before returning to the normal display.
6. DM860A Reboot mode
6.1.
Specifications
•
When DM860A is hung up, DM860A is restarted.
Even when Network standby is set (Setup Menu - Network - Network - Always ON), DM860A can be reset.
6.2.
Operation
1.
Turn on MAIN ZONE button, and select NETWORK for the input source.
2.
Press and hold the "TUNER PRESET CH +" and "STATUS" buttons for 3 seconds and longer.
3.
DM860A is restarted and returns to the normal display.
N e t w o r k
FLD
R e s t a r t
NOTE:
The same operation cannot be accepted for one minute after the last 860 Reboot.
51
www.audiodna.sk