4. Protection Pass Mode

4.1. Actions
• This mode allows the power to be turned on without activating protections.
• This mode functions in the same way as normal power-on, except that protections are not activated.
4.2. Operations
While holding down buttons "DIMMER", "STATUS" and "SOUND MODE" simultaneously, press the power button to turn
on the power.
The device returns to the normal display message after the following is displayed.
L1
P r o t e c t
FLD
L2
P a s s
L3
This is displayed for 5 seconds before returning to the normal display.

5. CY920 Reboot Mode

5.1. Actions
• The CY920 is restarted after CY920 hang up.
• The CY920 can be restarted even in the network standby setting.
("Setup menu" – "Network" – "Network" – "Always On")
5.2. Operations
(1) Turn the "MAIN ZONE" button on and set the input source to NETWORK.
(2) While the power is on, hold down buttons "TUNER PRESET CH +" and "STATUS" for at least 3 seconds.
Display during CY920 reboot
L1
N e t w o r k
FLD
L2
R e s t a r t
L3
(4) Returns to the normal display.
NOTE :
• After rebooting CY920, the same operation is not accepted for 1 minute.