Video Unit (2/3) - Marantz SR5008 Service Manual

Hide thumbs Also See for SR5008:
Table of Contents

Advertisement

A3V56S30FTP-G6 (HDMI:U2604,2605)
A3V56S30FTP-G6 Pin Function
Pin Descriptions
SYMBOL
CLK
CKE
/CS
/CAS,
/RAS,
/WE
DQM,
DQML,
DQMU,
BA0, BA1
A0–A12
DQ0–DQ15
NC
VddQ
VssQ
Vdd
Vss
Revision 1.1
TYPE
Clock: CLK is driven by the system clock. All SDRAM input signals are sampled on the positive
edge of CLK. CLK also increments the internal burst counter and controls the output registers.
Input
Clock Enable: CKE activates (HIGH) and deactivates (LOW) the CLK signal. Deactivating the
clock provides PRECHARGE POWER-DOWN and SELF REFRESH operation (all banks idle),
ACTIVE POWER-DOWN (row active in any bank), or CLOCK SUSPEND operation (burst /
access in progress). CKE is synchronous except after the device enters self refresh mode, where
Input
CKE becomes asynchronous until after exiting the same mode. The input buffers, including CLK,
are disabled during self refresh mode, providing low standby power. CKE may be tied HIGH.
Chip Select: /CS enables (registered LOW) and disables (registered HIGH) the command
decoder. All commands are masked when /CS is registered HIGH. /CS provides for external
Input
bank selection on systems with multiple banks. /CS is considered part of the command code.
Command Inputs: /CAS, /RAS, and /WE (along with /CS) define the command being entered.
Input
Input / Output Mask: DQM is sampled HIGH and is an input mask signal for write accesses and
an output disable signal for read accesses. Input data is masked during a WRITE cycle. The
output buffers are placed in a High-Z state (two-clock latency) when during a READ cycle. DQM
Input
corresponds to DQ0–DQ7 (A3V56S30FTP). DQML corresponds to DQ0–DQ7, DQMU
corresponds to DQ8–DQ15 (A3V56S40FTP).
Bank Address Input(s): BA0 and BA1 define to which bank the ACTIVE, READ, WRITE or
PRECHARGE command is being applied.
Input
A0-12 specify the Row / Column Address in conjunction with BA0,1. The Row Address is
specified by A0-12. The Column Address is specified by A0-9(x8) and A0-8(x16). A10 is also
used to indicate precharge option. When A10 is high at a read / write command, an auto
Input
precharge is performed. When A10 is high at a precharge command, all banks are precharged.
Data Input / Output: Data bus.
I/O
Internally Not Connected: These could be left unconnected, but it is recommended they be
connected or V
.
SS
Data Output Power: Provide isolated power to output buffers for improved noise immunity.
Supply
Data Output Ground: Provide isolated ground to output buffers for improved noise immunity.
Supply
Power for the input buffers and core logic.
Supply
Ground for the input buffers and core logic.
Supply