Details of Error code
Code
MainCPUfailedtoreceivefirmware
11
for rewriting sent from DM860A
(when an error occurred).
There was invalid data in the
firmwareforrewritingsentfrom
12
DM860A to Main CPU (when a
Check Sum error occurred).
The deletion of block data failed
13
before Main CPU was rewritten.
The rewriting of block data failed
14
when Main CPU was rewritten.
Thedataverificationwasinvalid
15
after Main CPU was rewritten.
Failure to acquire (Boot Loader
20
Mode) IP address before rewriting
DM860A (AutoIP).
Failure to acquire (Boot Loader
21
Mode) IP address before rewriting
DM860A (when timed out).
22
Log-in to DPMS failed.
Line, etc., is busy when logging into
23
DPMS.
24
Connection to DPMS failed.
25
Mode change failure of DM860A.
Data acquisition failed (timed out)
whenfirmwareofMainCPUwas
26
downloaded. Received Package
Version is wrong.
27
Mode change failure of DM860A.
Log-in to DPMS failed when Main
36
CPU was rewritten.
Line, etc., is busy when logging
37
into DPMS when Main CPU was
rewritten.
Display
(Eight digits or more are the scrolling displays.)
M a i n
1 1
U p d a t i n g
f a i l e d
M a i n
1 2
U p d a t i n g
f a i l e d
M a i n
1 3
E r a s e
f a i l e d
M a i n
1 4
U p d a t i n g
f a i l e d
M a i n
1 5
U p d a t e
C h e c k N G
C o n n e c t i o n
2 0
C o n n e c t i o n
2 1
L o g i n
f a i l e d
2 2
S e r v e r
i s
2 3
C o n n e c t i o n
2 4
C o n n e c t i o n
2 5
D o w n l o a d
f a i l
2 6
C o n n e c t i o n
2 7
M a i n
3 6
L o g i n
f a i l e d
M a i n
3 7
S e r v e r
i s
b u s y
62
www.audiodna.sk
Coping strategies
Turn off and on the power.
Updating starts automatically.
Turn off and on the power.
Updating starts automatically.
Turn off and on the power.
Updating starts automatically.
Turn off and on the power.
Updating starts automatically.
Turn off and on the power.
Updating starts automatically.
Check the network connection.
f a i l
Carry out the update in an environment
that has little network load.
Check the network connection.
f a i l
Carry out the update in an environment
that has little network load.
Reset and update again.
Carry out the update in an environment that
has little network load.
b u s y
Carry out the update in an environment
that has little network load.
Check the network connection.
f a i l
Carry out the update in an environment
that has little network load.
f a i l
Reset and update again.
Check the network connection.
Carry out the update in an environment
that has little network load.
f a i l
Reset and update again.
Carry out the update in an environment
that has little network load.
Carry out the update in an environment
that has little network load.