AMAX panel
7.1.2
LED/LCD Keypad Programming
An LED/LCD keypad can be used to program the system but only works with address
programming (please refer to Address Programming, page 110) as the programming menu can
not be displayed on the LED/LCD keypad. Therefore it is recommended to use a text keypad
or the PC software A-Link Plus for programming the system.
Accessing the Programming Menu
1.
2.
3.
P
Navigation
Programming an Option
1.
2.
3.
4.
5.
Exiting the Programming Mode
It is optional to save or not to save the programming data.
1.
2.
For LED/LCD keypads, the programming data is displayed by the number indicators, as
described in the graphic below.
Programming Data Indicators
Data
Value
0
1
2
3
4
5
6
7
8
9
10
11
Bosch Sicherheitssysteme GmbH
All manuals and user guides at all-guides.com
Confirm that the system is disarmed.
Enter the installer code. The default setting for the installer code is 1234.
Enter [958] + press the [#] key.
The STAY and AWAY indicators flash to indicate the programming mode.
Enter the required address and press [#].
Enter the desired data value and press [*] to confirm.
Press [#] to proceed to the next address.
Press [#] to exit.
Repeat step 1 if you want to program multiple options.
Enter [960] and press [#] to save the data and to exit the programming mode.
Enter [959] and press [#] to exit programming mode without saving the data.
Zone Indicators
1
2
X
X
X
X
Installation Manual
3
4
5
X
X
X
Configuration | en
6
7
8
X
X
X
X
2015.05 | 06 | F.01U.309.277
97
Mains
X
X