88
en | Configuration
Menu Items
TEST REPORT DURAT.
TEST RPT INTERV: h
TEST REPORT: hour
TEST REPORT: min
DUAL IP
REMOTE ACCESS
RPC IP/ PORT/ POLL
RPC IP ADDRESS
RPC PORT 5 DIGIT!
RPC POLL: 1-15h
CALLBACK/ DOMESTIC
RING TIMES
Figure 7.2: Communications and Reporting Manager (continued)
2015.05 | 06 | F.01U.309.277
All manuals and user guides at all-guides.com
REM. ACCESS ARMED
REMOTE PSTN ACCESS
REMOTE IP ACCESS
RPC ACCESS CODE
CALLBACK SETTING
CALLBACK/DOMEST No
DOMESTIC CALL
DOMESTIC No (1-4)
CHANGE DOM PHO. No
CALLBACK PHONE No
Installation Manual
Parameters / Description
00 = Do not use timing report
01 - 99 = 1 - 99 hours
00 - 23 hours Others = Do not use real-time report
00 - 59 minutes Others = Do not use real-time report
0-1 ip module
1-2 ip modules
0-disable 1-enable
0-disable 1-enable
0-disable 1-enable
0-disable 1-enable
0
= Panel does not answer
1 - 13 = Number of rings until the control panel responds
14
= Call the control panel and allow the phone to ring no
more than twice and hang up. Wait a minimum of 8 sec and
call the control panel again. The control panel answers on
the first ring.
15
= Call the control panel and allow the phone to ring no
more than four times and then hang up. If you call again
within 45 sec, the control panel answers the call on the first
ring.
AMAX panel
Certification
Default
EN=1-24
24
99
99
15
14
Bosch Sicherheitssysteme GmbH
1
1
1
1
0