18
en | Optional Modules and Peripheral Devices
Stable flash
Off
4.4
DX3010
4.4.1
General
The AMAX panel supports DX3010 output expansion modules. Each module supports 8 fully
programmable relay outputs.
For information on the installation, refer to Module Installation, page 26.
4.4.2
Address Setting
Each DX3010 module connected to the AMAX panel needs its own data bus address.
Data Bus Address
150
151*
Table 4.7: DX3010 Address Settings
DIP Switch
Data Bus Address
150
151*
Table 4.8: DX3010 DIP Switch Settings
* AMAX 3000 / 3000 BE / 4000
On
Figure 4.5: DX3010 DIP Switch Settings
4.4.3
Wiring
The following table and graphic show how to wire DX3010 to the option bus of the AMAX
panel.
Power Supply
AMAX panel
External power supply
Table 4.9: Lengths of cable for DX3010
2015.05 | 06 | F.01U.309.277
All manuals and user guides at all-guides.com
S1
1
On
Off
Off
O
N
D I P
1
2
3
4
5
6
Installation Manual
Normal Operation
Power failure
Outputs
5-12
13-20
S2
S3
2
4
On
On
On
On
Wire diameter of 0.8mm
12.2m
305m
S4
S5
S6
8
16
Mode
On
On
Off
On
On
Off
Wire diameter of 1.2mm
24.4m
610m
Bosch Sicherheitssysteme GmbH
AMAX panel