Mechanical (Kx) Thermostat; High Limit Thermostat - Vulcan-Hart VC4EC Service Manual

Vc4e & vc6e series full size electric convection ovens
Hide thumbs Also See for VC4EC:
Table of Contents

Advertisement

FULL SIZE ELECTRIC CONVECTION OVEN - REMOVAL AND REPLACEMENT OF PARTS
3.
Reverse procedure to install.
4.
Adjust the catch roller as outlined under DOOR
CATCH (ROLLER) ADJUSTMENT
(INDEPENDENT DOORS) in SERVICE
PROCEDURES AND ADJUSTMENTS.
MECHANICAL (KX)
THERMOSTAT
1.
Remove the racks and right rack support.
2.
Remove the thermostat knob and mounting
screws from the control panel and then remove
the control panel.
3.
Remove the probe guard from the oven cavity
wall.
NOTE: When installing probe guard, the probe
should not extend beyond the guard.
4.
Remove the thermostat bulb from the oven
cavity by pushing it through the oven wall and
into the control panel area.
NOTE: The hole in the oven cavity wall does not line
up straight with the oven cavity outer shell, therefore
the probe must be removed at an angle.
5.
Reverse the procedure to install.
6.
Adjust the thermostat as outlined under

MECHANICAL (KX) THERMOSTAT

CALIBRATION in SERVICE PROCEDURES
AND ADJUSTMENTS.

HIGH LIMIT THERMOSTAT

1.
Take out racks from the oven.
2.
Remove the high limit thermostat
cover/mounting plate from inside the oven
cavity at the top.
3.
Disconnect lead wires from high limit thermostat
then remove high limit thermostat from
cover/mounting plate.
Page 15 of 60
F25105 (Rev. A, October 2007)