Vent Valve Motor; Flow Meter; Temperature Probe; Safety Thermostat - Vulcan-Hart TCM Series Manufacturer's Instructions

Combi ovens
Hide thumbs Also See for TCM Series:
Table of Contents

Advertisement

9.11 VENT VALVE MOTOR

● Open the right-hand side of the oven:
- See the section on access to components «On the
side of the oven»
● Disconnect the electrical supply to the motor
● To remove the motor
- Slacken the bolt connecting the short shaft to the
motor several turns
It is advisable not to remove the bolt without supporting the
short shaft
- Undo the 2 nuts holding the motor to its support
- Remove the motor
● Change the motor
When refitting remember to retighten the connecting bolt
between the short shaft and the motor

9.12 FLOW METER

● Access to flow meter(s)
- Open the right-hand side of the oven:
See the section on access to components «On the
side of the oven»
● Disconnect the electrical supply to the flow meter
- Unscrew the connector fixing screw and disconnect it
from the flowmeter
● To remove the flow meter
- Cut the flowmeter fixing collar on the stainless-steel plate
- Disconnect hydraulically
Slacken the two clamps and pull the hoses off
the flow meter
● Change the flow meter

9.13 TEMPERATURE PROBE

● Access to temperature probe
- Open the right hand side of the oven:
See the section on access to components «On
the side of the oven»
● Déconnecter électriquement la sonde
- Unclip the terminal block from the FastPAD power
assembly
- Disconnect the two wires from the terminal
● To remove the probe
- Remove the holding clip
- Remove the probe and its seal
● Change the probe and seal
The probe seal must always be changed if the probe is
changed or removed for any reason (replaced or simply
checked)

9.14 SAFETY THERMOSTAT

● Access to the thermostat
- Open the right side of the oven :
See the chapter on access to components ʺon
the side of the oven"
● Electrically disconnect the thermostat
- Disconnect the two power terminals
● Removing the bulb
- Pull the bulb towards you
● Removing the thermostat
- Unscrew the fixing nut behind the plate
- Remove the thermostat and change it
When fitting the new bulb,,apply a dot of ʺmasticʺ at the
base of the thermowell.
Page 38
Connector fixing
screw
Probe
terminals
Thermostat
VULCAN
A division of ITW Food Equipment Group LLC
P.O. Box 696
Louisville, KY 40201
3VE490058EM – 12/21
Connecting bolt
Nuts
Ecrous
Attatch
ʺcable tieʺ
Seal
Dot of
ʺMasticʺ

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tcm-102eTcm-102gTcm-101eTcm-101gTcm-61g

Table of Contents