FULL SIZE ELECTRIC CONVECTION OVEN - REMOVAL AND REPLACEMENT OF PARTS
NOTE: Remove the old RTV sealer from the cover
and mating surfaces inside the oven cavity and apply
new high temperature RTV sealer before installing.
4.
Reverse procedure to install.

INTERIOR LIGHTS

Lamp
1.
Remove the racks.
2.
Unscrew the glass lens for the light being
replaced then unscrew the bulb.
3.
Replace bulb then reverse the procedure to
install.
Lamp Assembly
1.
Remove the lens and bulb.
2.
Remove the springs from the retaining tabs (2
places) on the socket.
3.
Depress the retaining tabs and pull the socket
out from the oven, far enough to disconnect the
lead wires.
4.
Remove the socket from the oven.
5.
Attach the lead wires to the replacement socket.
6.
Insert the socket into the hole in the oven and
push until the socket is held in place by the
retaining tabs.
7.
Install the light bulb and lens.
F25105 (Rev. A, October 2007)
8.
Check for proper operation.
1.
Remove the right side panel as outlined under
COVERS AND PANELS.
NOTE: If right side panel is not accessible, this
component can be serviced by removing the control
panel as outlined under COVERS AND PANELS.
2.
Disconnect the lead wires to the fan motor by
removing wire nuts.
3.
Remove the screws securing the air deflector to
the fan then loosen the tab screw holding the
fan to the component panel. Rotate the tab so
that the fan will clear and remove the fan.
4.
Reverse the procedure to install the
replacement fan and check for proper operation.
NOTE: The fan must be installed so air is pulled from
outside the rear of the oven and blown into the
control area. The arrow on the fan body indicates "air
flow" direction and should be pointing toward the
controls.
NOTE: Ensure fan is seated "squarely" against the
air tube and the oven bottom.
NOTE: The air deflector should be angled upwards
at approximately 30 degrees to properly direct the air
flow.