Computer Control Temperature Calibration - Vulcan-Hart VC4EC Service Manual

Vc4e & vc6e series full size electric convection ovens
Hide thumbs Also See for VC4EC:
Table of Contents

Advertisement

FULL SIZE ELECTRIC CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS
1.
Remove the right side panel as outlined under
COVERS AND PANELS.
2.
Turn the power switch ON.
A.
If the blower motor comes on, the SSR is
functioning properly.
B.
If the blower motor does not come on,
proceed to step 3.
3.
Check for +5 VDC on the input side of SSR
(terminals 3 & 4).
A.
If +5 VDC is present, continue to step 4.
B.
If no voltage is present, computer control is
not functioning properly.
4.
Check for proper input voltage on the load side
of SSR terminal 1 and the power connection on
the other side of the supply.
A.
On 208 & 240 volt ovens, the supply
connection is on the terminal block (L2 for
single phase, L3 for three phase).
The measured voltage should be identical
to the supply.
B.
On 480 volt ovens, the supply connection
is on the secondary side of the 480V
transformer, terminal X4 (wire # 79).
The measured voltage should be 240 volts.
5.
If input voltage is correct on the load side of
SSR terminal 1, proceed to step 6.
A.
If input voltage is not correct, find the
source of the problem.
6.
Check output voltage on the load side of SSR
terminal 2.
F25105 (Rev. A, October 2007)
A.
If voltage is correct, SSR is functioning
properly.
B.
If no voltage is present on the load side of
SSR terminal 2, the SSR is not functioning
properly.
7.
Turn the power switch OFF.
8.
Replace the SSR and check for proper
operation.
COMPUTER CONTROL
TEMPERATURE CALIBRATION
1.
Place a thermocouple in the geometric center of
the oven cavity.
2.
Turn the power switch ON.
A.
If the set point temperature is 350°F,
proceed to step 4.
B.
If the set point temperature is other than
350°F, proceed to step 3 to change the
temperature.
3.
Press the set key then temperature key to enter
the temperature set mode.
A.
The display will alternate between the term
"StPt" (set point) and the current oven
temperature setting.
B.
Press the up or down arrow keys to make
the proper selection.
C.
Press the set key again to save the change
and exit the temperature set mode.
4.
Allow the oven temperature to stabilize
(normally 3 cycles).
5.
Compare the controls set point temperature to
the thermocouple meter reading when the heat
light goes out.
A.
A temperature variance more than 5°F
indicates an adjustment is needed.
1)
2)
6.
Enter the setup mode as outlined in SETUP
MODE under COMPUTER CONTROL.
A.
Advance through the menu until CAL1
(Calibration Offset) appears.
Page 26 of 60
To make the adjustment, proceed to
step 6.
If temperature variance is less than
5°F, computer control is functioning
properly.