4. Field Settings

4.1

When 2 Units are Installed in 1 Room

Outline
When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding
wireless remote controller can be set for different address.
Procedure
1. Remove the battery cover of the remote controller.
2. Cut the address jumper (J4).
3. Press the center of TEMP button and MODE button on the remote controller at the same
4. Select A (address setting) with TEMP up or TEMP down button.
5. Press MODE button to enter the address setting mode.
6. Press the indoor unit ON/OFF switch while the operation lamp is blinking.
7. Press MODE button on the remote controller for 5 seconds to return to the normal mode.
Caution
Replace the remote controller if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.