Default Set Temperature Setting; Other Functions - Daikin FTKM-U Series Service Manual

Inverter pair wall mounted type r-32
Table of Contents

Advertisement

SiMX042215E

1.14 Default Set Temperature Setting

Outline
As per BEE regulation, whenever the air conditioner will be switched ON from the remote
controller, the default set temperature will be set as follows:
If set temperature < 24˚C
If set temperature >= 24˚C
If in dry operation
For example,
If switched OFF with 20 ˚C set, the unit will be restarted with 24 ˚C cooling mode.
If switched OFF with 26 ˚C set, the unit will be restarted with 26 ˚C cooling mode.
In the case of switched OFF with dry operation, the unit will be switched ON with cooling mode.
To keep dry operation when restarted, select dry operation mode again from the remote
controller.

1.15 Other Functions

1.15.1 Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal
receiving sound.
1.15.2 Indoor Unit ON/OFF Switch
Indoor unit ON/OFF switch is provided on the display of the unit.
 Press ON/OFF switch once to start operation. Press once again to stop it.
 ON/OFF switch is useful when the remote controller is missing or the battery has run out.
 The operation mode refers to the following table.
Forced Cooling Operation
Forced cooling operation can be started by pressing ON/OFF switch for 5 ~ 9 seconds while the
unit is not operating.
Refer to page 103 for details.
Note
Forced cooling operation will not be started if the ON/OFF switch is pressed for 10 seconds or
more.
1.15.3 Auto-restart Function
If a power failure (even a momentary one) occurs during the operation, the operation restarts
automatically in the same conditions as before when the power supply is restored to the
conditions prior to the power failure.
Note
It takes 3 minutes to restart the operation because 3-minute standby function is activated.
Part 4 Functions and Control
Previously switched OFF
Operation mode
Temperature setting
COOL
After switched ON again
Set temperature will be 24˚C.
Set temperature will be kept as previous setting.
Cooling operation with previously set temperature.
Airflow rate
22°C
Automatic
ON/OFF switch
Main Functions
R4003873
35