Technical Features - Siemens SIMOTICS T-1FW6 Configuration Manual

Built-in torque motors
Hide thumbs Also See for SIMOTICS T-1FW6:
Table of Contents

Advertisement

• To free jammed parts of the body (e.g. hands, fingers, feet), pull apart components that are
clamped together.
– Do this using the non-magnetic hammer to drive the non-magnetic wedges into the
– Release the jammed body parts.
• If necessary, call the emergency medical service or an emergency physician.
Material damage caused by strong magnetic fields
NOTICE
Data loss caused by strong magnetic fields
If you are close to the rotor (< 100 mm) any magnetic or electronic data medium as well as
electronic devices that you are carrying can be destroyed. For example, credit cards, USB sticks,
floppy disks and watches are at risk.
• Do not carry any magnetic/electronic data media and no electronic devices when you are
3.2.3

Technical features

Note
The values specified in the following table only apply in conjunction with the system
requirements described in Chapter "System integration (Page 428)".
Table 3-1
Standard version of the 1FW6 built-in torque motor
Technical feature
Type of motor
Type of construction
Degree of protection according to
DIN EN 60034-5
1FW6 Built-in torque motors
Configuration Manual, 09/2022, A5E52220645B AA
separating rift.
close to a rotor!
Version
Synchronous motor with permanent magnet rotor
High number of poles, rotor pole number from 22 up to 98
Individual components
Stator
Rotor
Motor: IP23
The final degree of protection (minimum degree of protection: IP54) of the
installed motor must be realized by the machine manufacturer
Description of the motor
3.2 Technical features and ambient conditions
37

Advertisement

Table of Contents
loading

Table of Contents