Siemens SIMATIC NET RUGGEDCOM MX5000RE Equipment Manual page 52

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM MX5000RE:
Table of Contents

Advertisement

Installing/removing media modules
Contamination hazard – risk of equipment damage
Prevent the ingress of water, dirt, and other debris that may lead to premature
equipment failure. Always make sure slots are not left empty and open ports are
protected with plugs or covers.
Changing media modules
With the exception of control (CM) and switch (SM) modules, all other media
modules are hot swappable. This allows you to replace a media module with one of
the same type while the device is in operation.
A system restart or reset to factory defaults may be required if:
For more information about hot swapping/hot plugging requirements, refer to the
"RUGGEDCOM ROX Configuration Manuals" [https://support.industry.siemens.com/
cs/ww/en/ps/21322/man]
Required tools/hardware
Torx T10 screwdriver
Removing a media module
To remove a media module, do the following:
1.
2.
3.
4.
RUGGEDCOM MX5000RE
Equipment Manual, 11/2023, C79000-G8976-1060-17
CAUTION
NOTICE
The new media module is of a different type
The module was installed in an empty slot while the device is in operation
Hardware
For control (CM) and switch (SM) modules only, make sure power to the device
has been disconnected and wait approximately two minutes for any remaining
energy to dissipate.
[Optional] If the device is installed in a rack, remove it from the rack.
Loosen the screws that secure the module.
Pull the media module from the chassis to disconnect it.
associated with the installed software release.
Quantity
1
Communication ports
3.1 Media modules
Detail
For removing/installing modules.
43