#6-32×5/8" SS304 Truss Head Philips Drive Screw
1
Patch Panel
2
Figure 2.14
Patch Panel Installation
2.
3.
4.
RUGGEDCOM MX5000RE
Equipment Manual, 11/2023, C79000-G8976-1060-17
Align the patch panel with the screw holes surrounding the patch panel
opening.
Apply Loctite® 242 to each screw.
Secure the patch panel to the enclosure with eight (8) screws for large panels,
or four (4) for small panels. Hand-tighten the screws evenly in a cross pattern.
There should be no visible gap between the patch panel and the enclosure's
bottom plate when properly tightened. Pay careful attention to avoid damaging
the cables and gaskets.
Installing the Device
2.11 Installing the Patch Panels