About this document Micropilot NMR81 About this document Document function The document is part of the Operating Instructions and serves as a reference for parameters, providing a detailed explanation of each individual parameter of the operating menu. Symbols 1.2.1 Safety symbols...
Page 5
Micropilot NMR81 About this document Symbol Meaning Cross-head screwdriver A0011219 Allen key A0011221 Hexagon wrench A0011222 1.2.4 Symbols for certain types of information Symbol Meaning Indicates additional information. Reference to documentation Reference to page Reference to graphic Operation via local display...
Overview of the operating menu Micropilot NMR81 Overview of the operating menu • The following table lists all parameters the "Expert" menu may contain. The page number refers to where a description of the parameter can be found. • Depending on the device version and parametrization some parameters will not be available in a given situation.
Page 7
Micropilot NMR81 Overview of the operating menu Backlight (0111) → 34 Contrast display (0105) → 34 ‣ System units → 36 Units preset (0605) → 36 Distance unit (0551) → 37 Pressure unit (0564) → 37 Temperature unit (0557) →...
Page 8
Overview of the operating menu Micropilot NMR81 ‣ Sensor → 52 ‣ Information → 53 Distance (12401) → 54 Sensor temp. (12499) → 54 Signal quality (12477) → 54 → 54 Abs. echo ampl. (12457) Relat.echo ampl.
Page 9
Micropilot NMR81 Overview of the operating menu End of mapping (12461) → 73 End map. ampl. (12478) → 74 ‣ Echo tracking → 76 Evaluation mode (12411) → 77 History reset (12449) → 77 ‣...
Page 10
Overview of the operating menu Micropilot NMR81 Output density (14720) → 86 Output temp. (14721) → 86 Output vapor tmp (14726) → 87 Output level (14718) → 87 ‣ HART device info → 89 ‣...
Page 11
Micropilot NMR81 Overview of the operating menu Cal type AIP (14018) → 111 Act. calibration (14012) → 112 Damping factor (14004) → 112 Gauge current (14027) → 112 ‣ Analog I/O → 113 Operating mode (13958) →...
Page 12
Overview of the operating menu Micropilot NMR81 Input val. in mA (13970) → 123 Input value [%] (13978) → 123 Damping factor (13951) → 123 Calibration (13966) → 123 Act. calibration (13981) → 124 → 124...
Page 13
Micropilot NMR81 Overview of the operating menu ‣ "Configuration" submenu (Modbus) → 135 Baudrate (13203) → 136 Parity (13204) Modbus address (13205) → 136 Float swap mode (13232) → 136 Invalid data (13243) → 137 Word type (13208) →...
Page 14
Overview of the operating menu Micropilot NMR81 ‣ UserVal source → 144 UserVal 1 to 8 source (13209–1 to 8) → 144 ‣ GP values → 145 GP 1 value 0% (13223) → 145 GP 1 value 100% (13224) →...
Page 15
Micropilot NMR81 Overview of the operating menu Alarm4 in-source (13284) → 154 SP1 value select (13274) → 155 SP2 value select (13275) → 155 SP3 value select (13276) → 156 SP4 value select (13277) → 156 Value % select (13282) →...
Page 16
Overview of the operating menu Micropilot NMR81 Device tag (0215) → 168 Device revision (0204) → 168 Device ID (0221) → 168 Device type (0209) → 168 Manufacturer ID (0259) → 169 → 169...
Page 17
Micropilot NMR81 Overview of the operating menu ‣ Temperature → 177 Liq temp source (14972) → 177 Man. liquid temp (15015) → 178 Liquid temp. (14978) → 178 Air temp. source (14993) → 178 Manual air temp. (14961) →...
The "Expert" menu Micropilot NMR81 Locking status Navigation Expert → Locking status (0004) Description Indicates curr. write protec. with highest prio. Additional information Read access Operator Write access Access stat.disp Navigation Expert → Access stat.disp (0091) Prerequisite The device has a local display.
Page 27
Micropilot NMR81 The "Expert" menu Additional information Read access Operator Write access Operator Endress+Hauser...
The "Expert" menu Micropilot NMR81 "System" submenu Navigation Expert → System ‣ System ‣ Display → 29 ‣ System units → 36 ‣ Date / time → 43 ‣ → 49 Administration Endress+Hauser...
Page 29
Micropilot NMR81 The "Expert" menu 3.1.1 "Display" submenu Navigation Expert → System → Display ‣ Display Language → 29 Format display → 30 Value 1 to 4 display → 30 → 31 Decimal places 1 to 4 →...
Page 30
The "Expert" menu Micropilot NMR81 • Svenska • Türkçe • 中文 (Chinese) • 日本語 (Japanese) • 한국어 (Korean) • (ا ل ْ ع َ ر َب ي ّةAra) • Bahasa Indonesia • ภาษาไทย (Thai) • tiếng Việt (Vit) • čeština (Czech)
Page 31
Micropilot NMR81 The "Expert" menu Description Select measured value that is shown on the display. Selection • None • Tank level • Measured level • Tank level % • Water level • Liquid temperature • Vapor temperature • Air temperature •...
Page 32
The "Expert" menu Micropilot NMR81 Selection • x • x.x • x.xx • x.xxx • x.xxxx Factory setting Additional information Read access Operator Write access Maintenance Separator Navigation Expert → System → Display → Separator (0101) Prerequisite The device has a local display.
Page 33
Micropilot NMR81 The "Expert" menu Header Navigation Expert → System → Display → Header (0097) Prerequisite The device has a local display. Description Select display header contents. Selection • Device tag • Free text Factory setting Device tag...
Page 34
The "Expert" menu Micropilot NMR81 Additional information Read access Operator Write access Operator Display damping Navigation Expert → System → Display → Display damping (0094) Prerequisite The device has a local display. Description Display reaction time to fluctuations of meas.val.
Page 35
Micropilot NMR81 The "Expert" menu Factory setting 30 % Additional information Read access Operator Write access Operator Endress+Hauser...
The "Expert" menu Micropilot NMR81 3.1.2 "System units" submenu Navigation Expert → System → System units ‣ System units Units preset → 36 Distance unit → 37 → 37 Pressure unit Temperature unit → 37 Density unit →...
Micropilot NMR81 The "Expert" menu Distance unit Navigation Expert → System → System units → Distance unit (0551) Description Select distance unit. Selection SI units US units • m • ft • mm • in • cm • ft-in-16 •...
The "Expert" menu Micropilot NMR81 Additional information Read access Operator Write access Maintenance (if Units preset (→ 36) = Customer value) Density unit Navigation Expert → System → System units → Density unit (0555) Description Select density unit.
Micropilot NMR81 The "Expert" menu Decimal pressure Navigation Expert → System → System units → Decimal pressure (0608) Description Number of decimal places for pressure values. Selection • x • x.x • x.xx • x.xxx • x.xxxx Factory setting x.xxx...
Page 40
The "Expert" menu Micropilot NMR81 Selection • x • x.x • x.xx • x.xxx • x.xxxx Factory setting Additional information Read access Operator Write access Maintenance The setting does not affect the accuracy of the measurement or the calculations. Endress+Hauser...
Page 41
Micropilot NMR81 The "Expert" menu 3.1.3 "Date / time" submenu The Date / time submenu is used to set the real-time clock of the device. Setting the real-time clock via the display and operating module 1. Navigate to Expert → System → Date / time → Set date.
Page 42
The "Expert" menu Micropilot NMR81 Setting the real-time clock via an operating tool (e.g. FieldCare) 1. Navigate to: Expert → System → Date / time Go to the Set date parameter (→ 44) and select the Start option. Use the following parameters to set the date and time: Year, Month, Day, Hour, Minutes.
Page 43
Micropilot NMR81 The "Expert" menu Structure of the submenu on the display and operating module Navigation Expert → System → Date / time ‣ Date / time Date/time → 44 ‣ Set date → 47 Date/time → 47 Year →...
Page 44
The "Expert" menu Micropilot NMR81 Description of parameters Navigation Expert → System → Date / time Date/time Navigation Expert → System → Date / time → Date/time (0790) Description Shows the current date and time from the real-time clock.
Page 45
Micropilot NMR81 The "Expert" menu Year Navigation Expert → System → Date / time → Year (0782) Prerequisite Set date (→ 44) = Start Description Enter the current year. User entry 2 016 to 2 079 Factory setting...
Page 46
The "Expert" menu Micropilot NMR81 Hour Navigation Expert → System → Date / time → Hour (0789) Prerequisite Set date (→ 44) = Start Description Enter the current hour. User entry 0 to 23 Factory setting Additional information...
Page 47
Micropilot NMR81 The "Expert" menu "Set date" wizard Navigation Expert → System → Date / time → Set date Date/time Navigation Expert → System → Date / time → Set date → Date/time (0790) Description → 44 Year ...
Page 48
The "Expert" menu Micropilot NMR81 Minute Navigation Expert → System → Date / time → Set date → Minute (0791) Description → 46 Set date Navigation Expert → System → Date / time → Set date → Set date...
Page 49
Micropilot NMR81 The "Expert" menu 3.1.4 "Administration" submenu Structure of the submenu on the display and operating module Navigation Expert → System → Administration ‣ Administration ‣ Def. access code → 51 Def. access code → 51 Confirm code →...
Page 50
The "Expert" menu Micropilot NMR81 Description of parameters Navigation Expert → System → Administration Def. access code Navigation Expert → System → Administration → Def. access code (0093) Description Define release code for write access to parameters.
Page 51
Micropilot NMR81 The "Expert" menu Selection • Cancel • To bus defaults • To fact.defaults • Restart device Factory setting Cancel Additional information Read access Operator Write access Maintenance "Define access code" wizard Navigation Expert → System → Administration → Def. access code Def.
Page 53
Micropilot NMR81 The "Expert" menu 3.2.1 "Information" submenu The Information submenu comprises all display parameters which give information about the current state of the measurement. Structure of the submenu Navigation Expert → Sensor → Information ‣ Information Distance → 54 →...
Page 54
The "Expert" menu Micropilot NMR81 Description of parameters Navigation Expert → Sensor → Information Distance Navigation Expert → Sensor → Information → Distance (12401) Description Distance from reference point to product surface. Additional information Read access Operator Write access Sensor temp.
Page 55
Micropilot NMR81 The "Expert" menu Relat.echo ampl. Navigation Expert → Sensor → Information → Relat.echo ampl. (12468) Description Relative amplitude of the evaluated level signal. Additional information Read access Operator Write access Tank bottom ampl Navigation Expert → Sensor → Information → Tank bottom ampl (12467) Description Shows the absolute amplitude of the tank bottom echo.
Page 56
The "Expert" menu Micropilot NMR81 3.2.2 "Filter options" submenu The Filter options submenu contains the parameters controlling the filtering of the distance signal. It consists of a low pass filter and a dead time. Low pass filter The low pass filter dampens the distance signal with a user defined integration time τ...
Page 57
Micropilot NMR81 The "Expert" menu Structure of the submenu Navigation Expert → Sensor → Filter options ‣ Filter options Integration time → 58 Dead time → 58 Endress+Hauser...
Page 58
The "Expert" menu Micropilot NMR81 Description of parameters Navigation Expert → Sensor → Filter options Integration time Navigation Expert → Sensor → Filter options → Integration time (12489) Description Sets the integration time of the distance filter.
Page 59
Micropilot NMR81 The "Expert" menu 3.2.3 "Sensor diagnostics" submenu The Sensor diag. submenu is used to check the anlog signal path. The test is started by the Start self check parameter (→ 59). A test signal is generated in the sensor module and fed onto the analog path.
Page 60
The "Expert" menu Micropilot NMR81 3.2.4 "Safety sett." submenu The Safety sett. submenu contains all parameters which determnine the behavior in case of an echo loss. Behavior in the case of an echo loss The bahavior in case of an echo loss is defined in the Output echo lost parameter (→...
Page 61
Micropilot NMR81 The "Expert" menu Structure of the submenu Navigation Expert → Sensor → Safety sett. ‣ Safety sett. Output echo lost → 62 Delay echo lost → 62 Endress+Hauser...
Page 62
The "Expert" menu Micropilot NMR81 Description of parameters Navigation Expert → Sensor → Safety sett. Output echo lost Navigation Expert → Sensor → Safety sett. → Output echo lost (12523) Description Output behavior in case of a lost echo.
Page 63
Micropilot NMR81 The "Expert" menu 3.2.5 "Mapping" submenu The mapping is used to suppress static interference signals which may be generatet by internal tank or silo fittings. A mapping curve, representing the envelope curve of an empty tank or silo as precisely as possible, is used for the mapping.
Page 64
The "Expert" menu Micropilot NMR81 Types of mapping Depending on the Confirm distance parameter (→ 71) there are different types of mapping: Confirm distance (→ 71) Type of mapping Description Factory map Factory map → 64 • Distance ok Overlay map →...
Page 65
Micropilot NMR81 The "Expert" menu In contrast to the overlay map, only the current envelope curve is used and there is no mapping overlay time. Therefore the new recording is faster than with the overlay map. However, dynamic interference echoes can not be suppressed in this way.
Page 66
The "Expert" menu Micropilot NMR81 Mapping range Depending on the Confirm distance parameter (→ 71), the mapping range is defined as follows: Confirm distance (→ 71) Starting point of mapping End point of mapping • Distance ok –250 mm (–9.8 in) automatically assigned according to the current •...
Page 67
Micropilot NMR81 The "Expert" menu Mapping in the tank bottom area Irrespective of the defined mapping range, no mapping is recorded in a gap near the end of the measuring range. The value of the map in this gap is defined by the follwong parameters: •...
Page 68
The "Expert" menu Micropilot NMR81 Deleting a map To delete a part of the map, proceed as follows: 1. Enter the end point of the area to be deleted into the Map. end point parameter (→ 72). 2. Go to the Record map parameter (→ 73) and select the Delete part. map option.
Page 69
Micropilot NMR81 The "Expert" menu Structure of the submenu on the local display Navigation Expert → Sensor → Mapping ‣ Mapping End of mapping → 73 End map. ampl. → 74 Structure of the mapping wizard on the local display Navigation ...
Page 70
The "Expert" menu Micropilot NMR81 Structure of the submenu in an operating tool Navigation Expert → Sensor → Mapping ‣ Mapping Distance → 71 Confirm distance → 71 Present mapping → 72 Map. end point → 72 Record map →...
The "Expert" menu Micropilot NMR81 • Distance too big To be selected if the measured distance exceeds the actual distance. The device adjusts the signal evaluation and returns to the Confirm distance parameter (→ 71). The distance is recalculated and displayed. The comparison must be repeated until the displayed distance matches the actual distance.
The "Expert" menu Micropilot NMR81 Factory setting Adjustable Additional information Read access Operator Write access Maintenance End map. ampl. Navigation Expert → Sensor → Mapping → End map. ampl. (12478) Description Specify the amplitude of the mapping curve in the tank bottom area.
Page 75
Micropilot NMR81 The "Expert" menu 3.2.6 "Echo tracking" submenu The echo tracking algorithm takes into account the short-time history of individual echoes when evaluating the envelope curve. This improves the identification of the level signal. The echo tracking can be activated in the Evaluation mode parameter (→ 77). A number of further parameters is used to configure the echo tracking more precisely.
Page 76
The "Expert" menu Micropilot NMR81 Structure of the submenu Navigation Expert → Sensor → Echo tracking ‣ Echo tracking Evaluation mode → 77 History reset → 77 Endress+Hauser...
Page 77
Micropilot NMR81 The "Expert" menu Description of parameters Navigation Expert → Sensor → Echo tracking Evaluation mode Navigation Expert → Sensor → Echo tracking → Evaluation mode (12411) Description Defines the evaluation mode for the echo tracking.
Page 78
The "Expert" menu Micropilot NMR81 3.2.7 "Tank bottom eval" submenu The tank bottom evaluation is used to prevent an echo loss if the tank is empty. The level echo is searched for in the measuring range defined by the Empty parameter (→...
Page 79
Micropilot NMR81 The "Expert" menu Structure of the "Tank bottom eval" submenu Navigation Expert → Sensor → Tank bottom eval ‣ Tank bottom eval Max.TB off dist. → 79 Description of parameters Navigation Expert → Sensor → Tank bottom eval Max.TB off dist.
Page 82
The "Expert" menu Micropilot NMR81 "HART Device(s)" submenu There is a HART Device(s) submenu for each HART slave device found on the HART loop. Navigation Expert → Input/output → HART devices → HART Device(s) ‣ HART Device(s) Device name →...
The "Expert" menu Micropilot NMR81 Additional information Read access Operator Write access Maintenance Comm. status Navigation Expert → Input/output → HART devices → HART Device(s) → Comm. status (14710) Description Shows the operating status of the transmitter. User interface •...
The "Expert" menu Micropilot NMR81 Output pressure Navigation Expert → Input/output → HART devices → HART Device(s) → Output pressure (14719) Prerequisite Not available for Micropilot S FMR5xx and Prothermo 53x. (In these cases the measured variables are allocated automatically).
Micropilot NMR81 The "Expert" menu Description Defines which HART variable is the temperature. Selection • No value • Primary var (PV) • Second.var(SV) • Tertiary var(TV) • Quaterna.var(QV) Factory setting No value Additional information Read access Operator Write access Maintenance Output vapor tmp ...
Page 88
The "Expert" menu Micropilot NMR81 Factory setting No value Additional information Read access Operator Write access Maintenance Endress+Hauser...
Micropilot NMR81 The "Expert" menu "HART device information" submenu Navigation Expert → Input/output → HART devices → HART Device(s) → HART device info ‣ HART device info Pressure → 89 Density → 90 Temperature → 90 Vapor temp.
Page 90
The "Expert" menu Micropilot NMR81 Additional information Read access Operator Write access Density Navigation Expert → Input/output → HART devices → HART Device(s) → HART device info → Density (14724) Prerequisite Output density (→ 86) ≠ No value Description Shows the density value from HART device.
Page 91
Micropilot NMR81 The "Expert" menu Water level Navigation Expert → Input/output → HART devices → HART Device(s) → HART device info → Water level (14717) Prerequisite Output level (→ 87) ≠ No value Description Shows the water level value.
Page 92
The "Expert" menu Micropilot NMR81 Manual value Navigation Expert → Input/output → HART devices → HART Device(s) → HART device info → Manual value (14746) Prerequisite Prothermo NMT53x with level measurement Description Shows the manual set level. User entry...
Page 93
Micropilot NMR81 The "Expert" menu Additional information Read access Operator Write access Device date Navigation Expert → Input/output → HART devices → HART Device(s) → HART device info → Device date (14707) Description Date of the connected device. Additional information...
Page 94
The "Expert" menu Micropilot NMR81 Additional information Read access Maintenance Write access Custody transfer Navigation Expert → Input/output → HART devices → HART Device(s) → HART device info → Custody transfer (14748) Prerequisite Prothermo NMT53x with temperature measurement Description Hardware lock status of NMT.
The "Expert" menu Micropilot NMR81 "NMT device config" submenu This submenu is only present if the connected HART device is a Prothermo NMT5xx. Navigation Expert → Input/output → HART devices → HART Device(s) → NMT dev. config ‣ NMT dev. config Config.
Page 99
Micropilot NMR81 The "Expert" menu Factory setting Additional information Meaning of the options • No Not configurable • Yes Configurable Read access Operator Write access Maintenance Access code Navigation Expert → Input/output → HART devices → HART Device(s) → NMT dev. config →...
Page 100
The "Expert" menu Micropilot NMR81 Factory setting 0 mm Additional information Read access Operator Write access Maintenance Temp elem. short Navigation Expert → Input/output → HART devices → HART Device(s) → NMT dev. config → Temp elem. short (14731) Description Sets the temp.
Page 101
Micropilot NMR81 The "Expert" menu Additional information Read access Operator Write access Maintenance Gain adjust Navigation Expert → Input/output → HART devices → HART Device(s) → NMT dev. config → Gain adjust (14736) Description Adjustm. of all temp. elements + reference 0 & 17.
Page 102
The "Expert" menu Micropilot NMR81 Description Shows the distance between the temp. elements. User entry Signed floating-point number Factory setting 0 mm Additional information Read access Operator Write access Maintenance "Element setup" submenu Navigation Expert → Input/output → HART devices → HART Device(s) →...
Page 103
Micropilot NMR81 The "Expert" menu Element temp. Navigation Expert → Input/output → HART devices → HART Device(s) → NMT dev. config → Element setup → Element temp. (14737) Description Shows the temperature of the element. Additional information Read access...
Page 104
The "Expert" menu Micropilot NMR81 "Forget device" wizard This submenu is only available if there is at least one unlocked device at the bus. Navigation Expert → Input/output → HART devices → Forget device Forget device Navigation Expert → Input/output → HART devices → Forget device → Forget device Description Deletes an offline device from the device list.
Page 105
Micropilot NMR81 The "Expert" menu 3.3.2 "Analog IP" submenu There is an Analog IP submenu for each Analog I/O module of the device. This submenu refers to terminals 4 to 8 of this module (the analog input). They are primarily used to connect an RTD. For terminals 1 to 3 (analog input or output) refer to →...
The "Expert" menu Micropilot NMR81 Process value Navigation Expert → Input/output → Analog IP → Process value (14003) Prerequisite Operating mode (→ 106) ≠ Disabled Description Shows the value received via the analog input. Additional information Read access...
Micropilot NMR81 The "Expert" menu 100 % value Navigation Expert → Input/output → Analog IP → 100 % value (14013) Prerequisite Operating mode (→ 106) = 4..20mA input Description The value represented by 20mA. User entry Signed floating-point number...
The "Expert" menu Micropilot NMR81 Temp. offset Navigation Expert → Input/output → Analog IP → Temp. offset (14025) Prerequisite Operating mode (→ 106) = RTD temp input Description Defines an offset for the measured temperature. The offset is applied after the resistance of the RTD has been converted to a temperature.
Page 111
Micropilot NMR81 The "Expert" menu Additional information Read access Operator Write access Maintenance Probe position Navigation Expert → Input/output → Analog IP → Probe position (14009) Prerequisite Operating mode (→ 106) = RTD temp input Description Position of the temperature probe, measured from zero position (tank bottom or datum plate).
Page 112
The "Expert" menu Micropilot NMR81 Act. calibration Navigation Expert → Input/output → Analog IP → Act. calibration (14012) Prerequisite Operating mode (→ 106) ≠ Disabled Description Shows calibration state of the analog input. Additional information Read access Operator...
Page 113
Micropilot NMR81 The "Expert" menu 3.3.3 "Analog I/O" submenu There is a Analog I/O submenu for each Analog I/O module of the device. This submenu refers to terminals 1 to 3 of this module (an analog input or output). For terminals 4 to 8 (always an analog input) refer to →...
The "Expert" menu Micropilot NMR81 Output value → 120 Readback value → 120 Feedback thresh. → 121 Process variable → 121 AI 0% value → 121 → 122 AI 100% value Error event type →...
Micropilot NMR81 The "Expert" menu Meaning of the options Operating mode (→ 114) Direction of signal Type of signal Disabled 4..20mA input Input from 1 external device Analog (4...20mA) HART ma.+4..20mA Input from 1 external device • Analog (4...20mA) •...
The "Expert" menu Micropilot NMR81 Meaning of the options Option Current range for process Lower alarm signal level Upper alarm signal level variable 4...20 mA 4 to 20.5 mA < 3.6 mA > 21.95 mA 4...20 mA NAMUR 3.8 to 20.5 mA <...
Micropilot NMR81 The "Expert" menu • Tank reference height • Liquid temperature • Vapor temperature • Air temperature • Observed density value • Average profile density • Upper density • Middle density • Lower density • P1 (bottom) • P2 (middle) •...
The "Expert" menu Micropilot NMR81 Error value Navigation Expert → Input/output → Analog I/O → Error value (13972) Prerequisite Failure mode (→ 117) = Defined value Description Defines the output value in case of an error. User entry 3.4 to 22.6 mA...
The "Expert" menu Micropilot NMR81 AI 100% value Navigation Expert → Input/output → Analog I/O → AI 100% value (13965) Prerequisite Operating mode (→ 114) = 4..20mA input or HART ma.+4..20mA Description Value corresp. to output current of 100% (20mA).
Micropilot NMR81 The "Expert" menu Input val. in mA Navigation Expert → Input/output → Analog I/O → Input val. in mA (13970) Prerequisite Operating mode (→ 114) = 4..20mA input or HART ma.+4..20mA Description Shows the input value in mA.
The "Expert" menu Micropilot NMR81 Description Calibration state of the analog input or output. Selection • Not calibrated • User calibration • Factory cal Factory setting Factory cal Additional information Read access Operator Write access Maintenance Act. calibration Navigation Expert → Input/output → Analog I/O → Act. calibration (13981) Prerequisite Operating mode (→...
Page 125
Micropilot NMR81 The "Expert" menu SIL/WHG chain Navigation Expert → Input/output → Analog I/O → SIL/WHG chain (13952) Prerequisite • Operating mode (→ 114) = 4..20mA output or HART slave • The device has a SIL approval. Additional information...
Page 126
The "Expert" menu Micropilot NMR81 3.3.4 "Digital Xx-x" submenu • In the operating menu, each digital input or output is designated by the respective slot of the terminal compartment and two terminals within this slot. A1-2, for example, denotes terminals 1 and 2 of slot A. The same is valid for slots B, C and D if they contain a Digital IO module.
The "Expert" menu Micropilot NMR81 Additional information Meaning of the options • Alarm x any, Alarm x H, Alarm x HH, Alarm x H or HH, Alarm x L, Alarm x LL, Alarm x L or LL The digital output indicates if the selected alarm is currently active. The alarms themselves are defined in the Alarm 1 to 4 submenus.
The "Expert" menu Micropilot NMR81 "Communication" submenu This menu contains a submenu for each digital communication interface of the device. The communication interfaces are designated by "X1-4" where "X" specifies the slot in the terminal compartmen and "1-4" the terminals within this slot.
Micropilot NMR81 The "Expert" menu 3.4.1 "Modbus Xx-x" or "V1 Xx-x" submenu This submenu is only present for devices with MODBUS and/or V1 communication interface. There is one submenu of this type for each communication interface. Navigation Expert → Communication → Modbus Xx-x / V1 Xx-x ‣...
The "Expert" menu Micropilot NMR81 Modbus value 1 to 4 Navigation Expert → Communication → Modbus Xx-x → Modbus value 1 to 4 (13206–1 to 4) Prerequisite Commu I/F protoc (→ 133) = MODBUS Description Shows the respective floating point value.
Micropilot NMR81 The "Expert" menu "Integer conversion" submenu Only visible for devices with a Modbus I/O module. Navigation Expert → Communication → Modbus Xx-x → Integer convers ‣ Integer convers → 139 Level 0% Level 100% → 140 Temperature 0% →...
Page 140
The "Expert" menu Micropilot NMR81 Level 100% Navigation Expert → Communication → Modbus Xx-x → Integer convers → Level 100% (13250) Description Level representing 100% on the integer scale. User entry Signed floating-point number Factory setting 30.0 mm...
Page 141
Micropilot NMR81 The "Expert" menu Pressure 0% Navigation Expert → Communication → Modbus Xx-x → Integer convers → Pressure 0% (13217) Description Pressure representing 0% on the integer scale. User entry Signed floating-point number Factory setting 0 bar...
Page 142
The "Expert" menu Micropilot NMR81 Density 100% Navigation Expert → Communication → Modbus Xx-x → Integer convers → Density 100% (13218) Description Density representing 100% on the integer scale. User entry Signed floating-point number Factory setting 1 000 kg/m³...
Page 143
Micropilot NMR81 The "Expert" menu Percent 0% Navigation Expert → Communication → Modbus Xx-x → Integer convers → Percent 0% (13202) Description Percentage representing 0% on the integer scale. User entry –200 to +400 % Factory setting 0.00 %...
The "Expert" menu Micropilot NMR81 "User value source" submenu Only visible for devices with a Modbus I/O module. Navigation Expert → Communication → Modbus Xx-x → UserVal source → UserVal 1 source (13209) UserVal 1 to 8 source ...
Micropilot NMR81 The "Expert" menu "GP values" submenu Navigation Expert → Communication → Modbus Xx-x → GP values → GP 1 value 0% (13223) ‣ GP values GP 1 value 0% → 145 GP 1 value 100% → 145 GP 2 value 0% →...
Page 146
The "Expert" menu Micropilot NMR81 Additional information Read access Operator Write access Maintenance GP 2 value 0% Navigation Expert → Communication → Modbus Xx-x → GP values → GP 2 value 0% (13257) Description GP2 value that represents 0% on integer scale.
Page 147
Micropilot NMR81 The "Expert" menu GP 3 value 100% Navigation Expert → Communication → Modbus Xx-x → GP values → GP 3 value 100% (13226) Description GP3 value that represents 100% on integer scale. User entry Signed floating-point number...
Micropilot NMR81 The "Expert" menu Additional information Read access Operator Write access Maintenance SP1 value select Navigation Expert → Communication → V1 → V1 input select. → SP1 value select (13274) Description Discrete value for V1 External Status bit 1.
Page 156
The "Expert" menu Micropilot NMR81 SP3 value select Navigation Expert → Communication → V1 → V1 input select. → SP3 value select (13276) Description Discrete value for V1 external status bit 3. Selection • None • Digital A1-2 •...
Page 157
Micropilot NMR81 The "Expert" menu Selection • None • Tank level % • Tank ullage % • AIO B1-3 value % • AIO C1-3 value % Factory setting None Additional information Read access Operator Write access Maintenance Endress+Hauser...
Page 158
The "Expert" menu Micropilot NMR81 3.4.2 "HART output" submenu Navigation Expert → Communication → HART output ‣ HART output ‣ Configuration → 159 ‣ Information → 167 Endress+Hauser...
Page 159
Micropilot NMR81 The "Expert" menu "Configuration" submenu Navigation Expert → Communication → HART output → Configuration ‣ Configuration Polling address → 159 No. of preambles → 160 PV source → 160 Assign PV → 160 0 % value →...
Page 160
The "Expert" menu Micropilot NMR81 Additional information Read access Operator Write access Maintenance No. of preambles Navigation Expert → Communication → HART output → Configuration → No. of preambles (0217) Description Number o preambles in the HART telegram.
Page 161
Micropilot NMR81 The "Expert" menu • Displacer pos • Water level • Upper I/F level • Lower I/F level • Bottom level • Tank ref height • Liquid temp. • Vapor temp. • Air temp. • Observed density • Profile density •...
Page 162
The "Expert" menu Micropilot NMR81 100 % value Navigation Expert → Communication → HART output → Configuration → 100 % value (11633) Prerequisite PV source = Custom Description 100% value of the primary variable (PV). User entry Signed floating-point number...
Page 163
Micropilot NMR81 The "Expert" menu Percent of range Navigation Expert → Communication → HART output → Configuration → Percent of range (0274) Description Shows percentage of the primary variable (PV). Additional information Read access Operator Write access Assign SV ...
Page 164
The "Expert" menu Micropilot NMR81 Additional information Read access Operator Write access Maintenance The Measured level option doesn' t contain a unit. If a unit is needed, select the Tank level option. Second.var(SV) Navigation Expert → Communication → HART output → Configuration → Second.var(SV)
Page 165
Micropilot NMR81 The "Expert" menu • GP 2 value • GP 3 value • GP 4 value Factory setting Water level Additional information Read access Operator Write access Maintenance The Measured level option doesn' t contain a unit. If a unit is needed, select the Tank level option.
Page 166
The "Expert" menu Micropilot NMR81 • Upper density • Middle density • Lower density • P1 (bottom) • P2 (middle) • P3 (top) • GP 1 value • GP 2 value • GP 3 value • GP 4 value Factory setting...
Page 167
Micropilot NMR81 The "Expert" menu "Information" submenu Navigation Expert → Communication → HART output → Information ‣ Information HART short tag → 167 Device tag → 168 Device revision → 168 Device ID → 168 Device type →...
Page 168
The "Expert" menu Micropilot NMR81 Device tag Navigation Expert → Communication → HART output → Information → Device tag (0215) Description Enter a unique name for the measuring point to identify the device quickly within the plant. Factory setting...
Page 169
Micropilot NMR81 The "Expert" menu User interface 0 to 65 535 Factory setting 4 395 Additional information Read access Operator Write access Manufacturer ID Navigation Expert → Communication → HART output → Information → Manufacturer ID (0259) Description For registration with HART Communic. Foundation.
Page 170
The "Expert" menu Micropilot NMR81 HART message Navigation Expert → Communication → HART output → Information → HART message (0216) Description User defined HART message (32 characters). Factory setting NMR8x Additional information Read access Operator Write access Maintenance Hardware rev.
Page 171
Micropilot NMR81 The "Expert" menu Factory setting 2009-07-20 Additional information Read access Operator Write access Maintenance Endress+Hauser...
The "Expert" menu Micropilot NMR81 Tank ref height Navigation Expert → Application → Tank config → Level → Tank ref height (14603) Description Distance from dipping ref. point to datum plate. User entry 0 to 100 000 mm...
The "Expert" menu Micropilot NMR81 Man. water level Navigation Expert → Application → Tank config → Level → Man. water level (14959) Prerequisite Water level src (→ 175) = Manual value Description Defines manual value of the bottom water level.
Page 177
Micropilot NMR81 The "Expert" menu "Temperature" submenu Navigation Expert → Application → Tank config → Temperature ‣ Temperature Liq temp source → 177 Man. liquid temp → 178 Liquid temp. → 178 Air temp. source → 178 Manual air temp.
Page 178
The "Expert" menu Micropilot NMR81 Man. liquid temp Navigation Expert → Application → Tank config → Temperature → Man. liquid temp (15015) Prerequisite Liq temp source (→ 177) = Manual value Description Defines the manual value of the liquid temperature.
Page 179
Micropilot NMR81 The "Expert" menu Manual air temp. Navigation Expert → Application → Tank config → Temperature → Manual air temp. (14961) Prerequisite Air temp. source (→ 178) = Manual value Description Defines the manual value of the air temperature.
Page 180
The "Expert" menu Micropilot NMR81 Man. vapor temp. Navigation Expert → Application → Tank config → Temperature → Man. vapor temp. (14960) Prerequisite Vapor temp src (→ 179) = Manual value Description Defines the manual value of the vapor temperature.
Page 181
Micropilot NMR81 The "Expert" menu "Density" submenu Navigation Expert → Application → Tank config → Density ‣ Density Density source → 181 Observed density → 182 Air density → 182 Vapor density → 182 UpDensity source →...
Page 182
The "Expert" menu Micropilot NMR81 Observed density Navigation Expert → Application → Tank config → Density → Observed density (13452) Description Shows the measured or calculated density. Additional information Read access Operator Write access Air density Navigation Expert → Application → Tank config → Density → Air density (14980) Description Density of the air surrounding the tank.
Page 183
Micropilot NMR81 The "Expert" menu Selection • Manual value • HART DEV 1 dens. • HART DEV 2 dens. • HART DEV 3 dens. • HART DEV 4 dens. • HART DEV 5 dens. • HART DEV 6 dens. • HART DEV 7 dens.
Page 184
The "Expert" menu Micropilot NMR81 Meas upper dens. Navigation Expert → Application → Tank config → Density → Meas upper dens. (15001) Description Shows the density of the upper phase. Additional information Read access Operator Write access Meas middle dens Navigation ...
Micropilot NMR81 The "Expert" menu P1 position Navigation Expert → Application → Tank config → Pressure → P1 position (14952) Description Position of the bottom pressure transmitter (P1). User entry –10 000 to 100 000 mm Factory setting...
Micropilot NMR81 The "Expert" menu P2 offset Navigation Expert → Application → Tank config → Pressure → P2 offset (14975) Description Defines the offset for the middle pressure (P2). The offset is added to the measured pressure prior to any tank calculation.
Micropilot NMR81 The "Expert" menu P3 position Navigation Expert → Application → Tank config → Pressure → P3 position (14956) Description Position of the top pressure transmitter (P3). User entry 0 to 100 000 mm Factory setting 20 000 mm...
The "Expert" menu Micropilot NMR81 Ambient pressure Navigation Expert → Application → Tank config → Pressure → Ambient pressure (14962) Description Manual value of the ambient pressure. User entry 0 to 2.5 bar Factory setting 1 bar Additional information...
Page 193
Micropilot NMR81 The "Expert" menu "GP values" submenu Navigation Expert → Application → Tank config → GP values ‣ GP values GP 1 to 4 source → 193 GP 1 to 4 name → 194 GP Value 1 →...
Page 194
The "Expert" menu Micropilot NMR81 GP 1 to 4 name Navigation Expert → Application → Tank config → GP values → GP 1 name (14963) Description Defines the label for the respective GP value. Factory setting GP Value 1...
Page 195
Micropilot NMR81 The "Expert" menu GP Value 4 Navigation Expert → Application → Tank config → GP values → GP Value 4 (14969) Description General purpose values. Additional information Read access Operator Write access Endress+Hauser...
Page 196
The "Expert" menu Micropilot NMR81 3.5.2 "Tank calculation" submenu Navigation Expert → Application → Tank calculation ‣ Tank calculation Local gravity → 196 ‣ HyTD → 199 ‣ → 204 CTSh ‣ HTMS → 209 ‣...
Page 197
Micropilot NMR81 The "Expert" menu "HyTD" submenu Overview Hydrostatic Tank Deformation can be used to compensate the vertical movement of the Gauge Reference Height (GRH) due to bulging of the tank shell caused by the hydrostatic pressure exerted by the liquid stored in the tank. The compensation is based on a linear approximation obtained from manual hand dips at several levels distributed over the full range of the tank.
Page 198
The "Expert" menu Micropilot NMR81 Linear approximation of the HyTD correction The real amount of deformation varies non-linearly with the level due to the construction of the tank. However, as the correction values are typically small compared to the measured level, a simple straight line method can be used with good results.
Page 199
Micropilot NMR81 The "Expert" menu Description of parameters Navigation Expert → Application → Tank calculation → HyTD ‣ HyTD HyTD corr. value → 199 HyTD mode → 199 Starting level → 199 Deform factor → 200 HyTD corr.
Page 200
The "Expert" menu Micropilot NMR81 User entry 0 to 5 000 mm Factory setting 500 mm Additional information Read access Operator Write access Maintenance Deform factor Navigation Expert → Application → Tank calculation → HyTD → Deform factor (13602) Description Deformation factor for the HyTD.
Page 201
Micropilot NMR81 The "Expert" menu "CTSh" submenu Overview CTSh (correction of the thermal tank shell expansion) compensates for effects on the Gauge Reference Height (GRH) due to temperature effects on the tank shell or stilling well. The temperature effects are separated into two parts, respectively effecting the ' d ry' and ' w etted' part of the tank shell or stilling well.
Page 202
The "Expert" menu Micropilot NMR81 CTSh: Calculation of the wall temperature A0028712 12 Parameters for the CTSh calculation Gauge Reference Height (GRH) Temperature of the wetted part of the tank shell Temperature of the dry part of the tank shell...
Page 203
Micropilot NMR81 The "Expert" menu A0030382 Covered tank (→ 205) = Covered; Stilling well (→ 205) = Yes Covered tank (→ 205) = Covered; Stilling well (→ 205) = No Covered tank (→ 205) = Open top; Stilling well (→ 205) = Yes Covered tank (→...
Page 204
The "Expert" menu Micropilot NMR81 CTSh: Calculation of the correction = (H - L)(T - T ) + L (T - T ) α α CTSh A0028716 Gauge Reference Height Measured level Temperature of the dry part of the tank shell (calculated from T...
Page 205
Micropilot NMR81 The "Expert" menu CTSh mode Navigation Expert → Application → Tank calculation → CTSh → CTSh mode (14651) Description Activates or deactivates the CTSh. Selection • No • Yes Factory setting Additional information Read access Operator...
Page 206
The "Expert" menu Micropilot NMR81 Calibration temp Navigation Expert → Application → Tank calculation → CTSh → Calibration temp (13652) Description Temperature during calibration of the measurement. User entry –50 to 250 °C Factory setting 25 °C Additional information...
Page 207
Micropilot NMR81 The "Expert" menu "HTMS" submenu Overview The Hybrid Tank Measurement System (HTMS) is a method to calculate the density of a product in a tank based on both a (top mounted) level and at least one (bottom mounted) pressure measurement.
Page 208
The "Expert" menu Micropilot NMR81 HTMS modes Two HTMS modes can be selected in the HTMS mode parameter (→ 209). The mode determines whether one or two pressure values are used. Depending on the selected mode a number of additional parameters are required for the calculation of the product density.
Page 209
Micropilot NMR81 The "Expert" menu Lmin A0029148 14 HTMS hysteresis Value calculated Value held/manual Min. level (→ 210) Hysteresis (→ 211) Description of parameters Navigation Expert → Application → Tank calculation → HTMS ‣ HTMS HTMS mode →...
Page 210
The "Expert" menu Micropilot NMR81 Additional information Read access Operator Write access Maintenance Meaning of the options • HTMS P1 Only a bottom pressure transmitter (P1) is used. • HTMS P1+P3 A bottom (P1) and top (P3) pressure transmitter are used. This option should be selected for pressurized tanks.
Page 211
Micropilot NMR81 The "Expert" menu Additional information Read access Operator Write access Maintenance Min. pressure Navigation Expert → Application → Tank calculation → HTMS → Min. pressure (13754) Description Defines the minimum pressure for a HTMS calculation. If the pressure P1 falls below the limit defined in this parameter, the density retains its last value or the manual value is used instead.
Page 212
The "Expert" menu Micropilot NMR81 Water density Navigation Expert → Application → Tank calculation → HTMS → Water density (13757) Description Density of the water in the tank. User entry Signed floating-point number Factory setting 1 000 kg/m³...
Page 213
Micropilot NMR81 The "Expert" menu "Dip-table" submenu Dip table The dip table is used to correct the level readings using independently taken hand dips. The dip table is used in particular to adapt the level gauge to the specific application conditions such as a mechanical offset and the tank or stilling well design.
Page 214
The "Expert" menu Micropilot NMR81 The table editor on the local display 1. Navigate to Setup → Advanced setup → Application → Tank calculation → Dip-table → Table mode (12516) and select the Disable option. 2. Navigate to Setup → Advanced setup → Application → Calculation → Dip-table → Edit table ...
Page 215
Micropilot NMR81 The "Expert" menu The table editor in FieldCare In the FieldCare table editor the dip table can only be entered manually. Even if the semiautomatic method has been selected in the Table settings parameter (→ 216), the complete table will be written from the editor to the device in the manual mode.
Page 216
The "Expert" menu Micropilot NMR81 Description of parameters Navigation Expert → Application → Tank calculation → Dip-table ‣ Dip-table Table settings → 216 Table mode → 216 Table settings Navigation Expert → Application → Tank calculation → Dip-table → Table settings (12515) Description Defines the dip-table operation to be performed.
Page 217
Micropilot NMR81 The "Expert" menu Factory setting Disable Additional information Read access Operator Write access Maintenance Endress+Hauser...
Page 219
Micropilot NMR81 The "Expert" menu Alarm mode Navigation Expert → Application → Alarm → Alarm → Alarm mode (13864) Description Defines the alarm mode of the selected alarm. Selection • Off • On • Latching Factory setting Additional information...
Page 220
The "Expert" menu Micropilot NMR81 A0029539 16 Principle of the limit evaluation Alarm mode (→ 219) = On Alarm mode (→ 219) = Latching HH alarm value (→ 222) H alarm value (→ 222) L alarm value (→ 223) LL alarm value (→...
Page 221
Micropilot NMR81 The "Expert" menu Alarm source Navigation Expert → Application → Alarm → Alarm → Alarm source (13866) Prerequisite Alarm mode (→ 219) ≠ Off Description Determines the process variable to be monitored. Selection • Tank level •...
Page 222
The "Expert" menu Micropilot NMR81 Alarm value Navigation Expert → Application → Alarm → Alarm → Alarm value (13863) Prerequisite Alarm mode (→ 219) ≠ Off Description Current value of the variable being monitored. User interface Signed floating-point number...
Page 223
Micropilot NMR81 The "Expert" menu L alarm value Navigation Expert → Application → Alarm → Alarm → L alarm value (13853) Prerequisite Alarm mode (→ 219) ≠ Off Description Defines the low limit value. User entry Signed floating-point number...
Page 224
The "Expert" menu Micropilot NMR81 H alarm Navigation Expert → Application → Alarm → Alarm → H alarm (13856) Prerequisite Alarm mode (→ 219) ≠ Off Description Shows whether an H alarm is currently active. Additional information Read access...
Page 225
Micropilot NMR81 The "Expert" menu Additional information Read access Operator Write access LL+L alarm Navigation Expert → Application → Alarm → Alarm → LL+L alarm (13869) Prerequisite Alarm mode (→ 219) ≠ Off Description Shows if an LL or L alarm is currently active.
Page 226
The "Expert" menu Micropilot NMR81 Additional information Read access Operator Write access Maintenance Alarm hysteresis Navigation Expert → Application → Alarm → Alarm → Alarm hysteresis (13862) Prerequisite Alarm mode (→ 219) ≠ Off Description Defines the hysteresis for the limit values.
Micropilot NMR81 The "Expert" menu "Tank values" submenu Navigation Expert → Tank values ‣ Tank values ‣ Level → 227 ‣ Temperature → 231 ‣ Density → 234 ‣ Pressure → 236 ‣ GP values →...
Page 228
The "Expert" menu Micropilot NMR81 Tank level Navigation Expert → Tank values → Level → Tank level (14655) Description Shows distance from zero to product surface. Additional information Read access Operator Write access Tank Level % Navigation Expert → Tank values → Level → Tank Level % (14654) Description Level measured in percent.
Page 229
Micropilot NMR81 The "Expert" menu Upper I/F level Navigation Expert → Tank values → Level → Upper I/F level (15003) Description Up I/F Level measured from zero position. Additional information Read access Maintenance Write access Lower I/F level Navigation ...
Page 230
The "Expert" menu Micropilot NMR81 Measured level Navigation Expert → Tank values → Level → Measured level (14653) Description Shows the measured level without any correction. Additional information Read access Operator Write access Distance Navigation Expert → Tank values → Level → Distance (12401) Description Distance from reference point to product surface.
Page 231
Micropilot NMR81 The "Expert" menu 3.6.2 "Temperature" submenu Navigation Expert → Tank values → Temperature ‣ Temperature Liquid temp. → 231 Vapor temp. → 231 Air temp. → 232 ‣ → 232 NMT elem. values ‣...
Page 232
The "Expert" menu Micropilot NMR81 Air temp. Navigation Expert → Tank values → Temperature → Air temp. (14986) Description Shows the air temperature. Additional information Read access Operator Write access "NMT element values" submenu Navigation Expert → Tank values → Temperature → NMT elem. values "Element temperature"...
Page 233
Micropilot NMR81 The "Expert" menu Additional information Read access Operator Write access Endress+Hauser...
Page 234
The "Expert" menu Micropilot NMR81 3.6.3 "Density" submenu Navigation Expert → Tank values → Density ‣ Density Observed density → 234 Vapor density → 234 → 235 Air density Meas upper dens. → 235 Meas middle dens →...
Page 235
Micropilot NMR81 The "Expert" menu Air density Navigation Expert → Tank values → Density → Air density (14980) Description Density of the air surrounding the tank. User entry 0.0 to 500.0 kg/m³ Factory setting 1.2 kg/m³ Additional information...
Page 236
The "Expert" menu Micropilot NMR81 3.6.4 "Pressure" submenu Navigation Expert → Tank values → Pressure ‣ Pressure P1 (bottom) → 236 P3 (top) → 236 P1 (bottom) Navigation Expert → Tank values → Pressure → P1 (bottom) (14983) Description Shows the pressure at the tank bottom.
Page 237
Micropilot NMR81 The "Expert" menu 3.6.5 "GP values" submenu Navigation Expert → Tank values → GP values ‣ GP values GP 1 to 4 name → 237 GP Value 1 → 237 GP Value 2 → 237 →...
Page 238
The "Expert" menu Micropilot NMR81 Additional information Read access Operator Write access GP Value 3 Navigation Expert → Tank values → GP values → GP Value 3 (14968) Description General purpose values. Additional information Read access Operator Write access...
Micropilot NMR81 The "Expert" menu "Diagnostics" submenu Navigation Expert → Diagnostics ‣ Diagnostics Actual diagnos. → 241 Timestamp → 241 Prev.diagnostics → 241 Timestamp → 242 Time fr. restart → 242 → 242 Operating time →...
Page 240
The "Expert" menu Micropilot NMR81 Firmware version → 251 Firmware CRC → 251 W&M config CRC → 251 Device name → 252 Order code → 252 → 252 Ext. order cd. 1 to 3 ENP version →...
Page 241
Micropilot NMR81 The "Expert" menu Actual diagnos. Navigation Expert → Diagnostics → Actual diagnos. (0691) Description Current occured diag. event with its diag. info. Additional information Read access Operator Write access The display consists of: • Symbol for event behavior •...
Page 242
The "Expert" menu Micropilot NMR81 The display consists of: • Symbol for event behavior • Code for diagnostic behavior • Operating time of occurrence • Event text If several messages are active at the same time, the messages with the highest priority is displayed.
Page 243
Micropilot NMR81 The "Expert" menu Date/time Navigation Expert → Diagnostics → Date/time (0790) Description Displays the device internal real time clock. Additional information Read access Operator Write access Endress+Hauser...
Page 244
The "Expert" menu Micropilot NMR81 3.7.1 "Diagnostic list" submenu Navigation Expert → Diagnostics → Diagnostic list ‣ Diagnostic list Diagnostics 1 to 5 → 244 Timestamp 1 to 5 → 244 Diagnostics 1 to 5 Navigation Expert → Diagnostics → Diagnostic list → Diagnostics 1 to 5 (0692–1 to 5) Description Display the current diagnostics messages with the highest to fifth-highest priority.
Page 245
Micropilot NMR81 The "Expert" menu 3.7.2 "Event logbook" submenu Structure of the submenu on the local display Navigation Expert → Diagnostics → Event logbook ‣ Event logbook Filter options → 245 ‣ Event list → 245 Description of parameters Navigation ...
Page 246
The "Expert" menu Micropilot NMR81 The following status symbols indicate, whether an event has appeared or disappeared at the time stated: • : Event appeared • : Event disappeared Remedy measures concerning the cause of the message can be called up via the symbol on the display.
Page 248
The "Expert" menu Micropilot NMR81 Additional information Read access Operator Write access Maintenance To terminate the simulation, select Off. Sim distance on Navigation Expert → Diagnostics → Simulation → Sim distance on (12475) Description Switches the distance simulation on or off.
Page 249
Micropilot NMR81 The "Expert" menu Selection • Off • On Factory setting Additional information Read access Operator Write access Maintenance Simulation value Navigation Expert → Diagnostics → Simulation → Simulation value (13976) Expert → Diagnostics → Simulation → Simulation value (13976) Prerequisite Curr.out.
Page 250
The "Expert" menu Micropilot NMR81 3.7.4 "Device information" submenu Navigation Expert → Diagnostics → Device info ‣ Device info Device tag → 250 Serial number → 251 → 251 Firmware version Firmware CRC → 251 W&M config CRC...
Page 251
Micropilot NMR81 The "Expert" menu Serial number Navigation Expert → Diagnostics → Device info → Serial number (0009) Description Shows the serial number of the measuring device. Additional information Read access Operator Write access Firmware version Navigation Expert → Diagnostics → Device info → Firmware version (0010) Description Shows the device firmware version installed.
Page 252
The "Expert" menu Micropilot NMR81 Device name Navigation Expert → Diagnostics → Device info → Device name (0013) Description Shows the name of the transmitter. Additional information Read access Operator Write access Order code Navigation Expert → Diagnostics → Device info → Order code (0008) Description Shows the device order code.
Page 253
Micropilot NMR81 The "Expert" menu Device type Navigation Expert → Diagnostics → Device info → Device type (8561) Description Displays the device type. Additional information Read access Operator Write access Module type Navigation Expert → Diagnostics → Device info → Module type (8526) Description Shows the type of installed IO module.
Page 254
The "Expert" menu Micropilot NMR81 "Board info" submenu Navigation Expert → Diagnostics → Device info → Board info ‣ Board info Date/time → 254 System temp. → 254 W&M lock switch → 254 Date/time Navigation Expert → Diagnostics → Device info → Board info → Date/time (0790) Description Shows the current date and time from the real-time clock.
Page 255
Micropilot NMR81 The "Expert" menu User interface • Enabled • Disabled Factory setting Enabled Additional information Read access Operator Write access Endress+Hauser...
Page 256
The "Expert" menu Micropilot NMR81 3.7.5 "Data logging" submenu Structure of the submenu on the local display Navigation Expert → Diagnostics → Data logging ‣ Data logging Assign chan. 1 to 4 → 257 Logging interval → 258 Clear logging →...
Page 257
Micropilot NMR81 The "Expert" menu Description of parameters Navigation Expert → Diagnostics → Data logging Assign chan. 1 to 4 Navigation Expert → Diagnostics → Data logging → Assign chan. 1 (0851) Description Assign a process variable to logging channel.
Page 258
The "Expert" menu Micropilot NMR81 Additional information A total of 1000 measured values can be logged. This means: • 1000 data points if 1 logging channel is used • 500 data points if 2 logging channels are used • 333 data points if 3 logging channels are used •...
Page 259
Micropilot NMR81 The "Expert" menu Clear logging Navigation Expert → Diagnostics → Data logging → Clear logging (0855) Expert → Diagnostics → Data logging → Clear logging (0855) Description Clear the entire logging data. Selection • Cancel •...
Page 260
The "Expert" menu Micropilot NMR81 "Displ.channel 1 to 4" submenu The Displ.channel 1 to 4 submenu is only available when operating via the local display. When operating via FieldCare, the diagram can be displayed in the "Event List / HistoROM" function.
Page 261
Micropilot NMR81 The "Expert" menu 3.7.6 "Device check" submenu Navigation Expert → Diagnostics → Device check ‣ Device check Start dev. check → 261 Result dev.check → 261 Level signal → 262 → 262 Near distance →...
Page 262
The "Expert" menu Micropilot NMR81 Level signal Navigation Expert → Diagnostics → Device check → Level signal (12483) Prerequisite Only visible after a device check. Description Result of the device check for the level signal. Additional information Read access...