Fs A 0 N - Epson TM-U925 Manual

1.5 station printer
Hide thumbs Also See for TM-U925:
Table of Contents

Advertisement

FS a 0 n

[Name]
Read check paper
[Format]
ASCII
Hex
Decimal
0 £ n £ 255
[Range]
[Description] Selects the MICR function and reads MICR characters specified by n as follows:
Bit
Off/On
Off
0
On
Off
1
On
Off
2
On
Off
3
On
Off
4
On
Off
5
On
Off
6
On
Off
7
On
Readable Fonts
Bit 1
Bit 0
0
0
0
1
1
0
1
1
· This command is enabled only when input at the beginning of a line.
[Notes]
· Since this command is executed after being buffered, there may be a time lag between
command reception and starting MICR reading.
· When an undefined font is selected, this command is ignored.
· If the MICR function is not selected while this command is processed, the printer enters
the check paper waiting status. When slip paper is selected for printing, the printer
ejects the current slip, then waits for the next slip to be loaded.
· The time specified by ESC f is effective. t1 indicates the time from processing this
command to inserting check paper, and t2 indicates the time from detecting check
paper to loading it.
EPSON
FS
a
1C
61
28
97
Hex
Decimal
00
0
01
1
Readable fonts. Refer to the table below.
00
0
02
2
00
0
Undefined.
04
4
Undefined.
00
0
Undefined.
08
8
Undefined.
00
0
Undefined.
10
16
Undefined.
00
0
Undefined.
20
32
Undefined.
00
0
Undefined.
40
64
Undefined.
00
0
Undefined.
80
128
Undefined.
Font
E13B
CMC7
Undefined
Undefined
TITLE
TM-U925
Specification
(STANDARD)
0
n
30
n
48
n
Function
SHEET
REVISION
A
NO.
NEXT
SHEET
113
112

Advertisement

Table of Contents
loading

Table of Contents