Endress+Hauser Levelflex FMP51 Technical Information
Endress+Hauser Levelflex FMP51 Technical Information

Endress+Hauser Levelflex FMP51 Technical Information

Guided level-radar
Hide thumbs Also See for Levelflex FMP51:
Table of Contents

Advertisement

Quick Links

Technical Information
Levelflex FMP51, FMP52, FMP54
Guided Level-Radar
Level and interface measurement in liquids
TI01001F/00/EN/10.10
71120833
Application
• FMP51 - premium device for level and interface
masurment in liquids.
• FMP52 - premium device with coated probe for the
use in aggressive liquids. Wetted parts FDA listed
materials.
• FMP54 - premium device for high-temperature and
high-pressure applications, mainly in liquids.
• Measuring range up to 45 m (148 ft)
• Process connection starting 3/4" thread or flange
• Temperature range:
–196 to +450 °C (–321 to +842 °F)
• Pressure range: –1 to 400 bar (–14.5 to 5 800 psi)
• The following interfaces are available for system
integration:
HART with 4...20 mA analog
• Used for level monitoring (MIN, MAX, range) up to
SIL 3 (homogeneous redundancy), independently
assessed by TÜV as per IEC 61508
Your benefits
• Reliable measuring:
– in case of moved surface and foam
– for changing medias
– in dust applications (FMP54 only)
• High availablility
• Integrated data memory
• Factory precalibrated
• Intuitive, menu-guided operating concept in national
languages
• Simple integration into control or asset management
systems
• Exact instrument and process diagnosis to assist fast
decisions
• Approvals: ATEX, IEC Ex, CSA, FM
Pressure Equipment Directive PED (FMP54 only)

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Levelflex FMP51

  • Page 1 Technical Information Levelflex FMP51, FMP52, FMP54 Guided Level-Radar Level and interface measurement in liquids Application • FMP51 - premium device for level and interface masurment in liquids. • FMP52 - premium device with coated probe for the use in aggressive liquids. Wetted parts FDA listed materials.
  • Page 2: Table Of Contents

    Table of contents Levelflex FMP51, FMP52, FMP54 Table of contents Important document information ....4 Degree of protection ......42 Vibration resistance .
  • Page 3 Levelflex FMP51, FMP52, FMP54 Table of contents Patents ........76...
  • Page 4: Important Document Information

    Levelflex FMP51, FMP52, FMP54 Important document information Document conventions Electrical symbols Symbol Meaning Direct current A terminal to which DC voltage is applied or through which direct current flows. A0011197 Alternating current A terminal to which alternating voltage (sine-wave) is applied or through which alternating current flows.
  • Page 5: Function And System Design

    Levelflex FMP51, FMP52, FMP54 Function and system design Measuring principle Level measurement The Levelflex is a "downward-looking" measuring system that functions according to the ToF method (ToF = Time of Flight). The distance from the reference point to the product surface is measured. High-frequency pulses are injected to a probe and led along the probe.
  • Page 6 Levelflex FMP51, FMP52, FMP54 Output The Levelflex is preset at the factory to the probe length ordered so that in most cases only the application parameters that automatically adapt the device to the measuring conditions need to be entered. For models with a current output, the factory adjustment for zero point E and span F is 4 mA and 20 mA, for digital outputs and the display module 0 % and 100 %.
  • Page 7 • Hardware and software developed according to SIL IEC 61508 • Genuine, direct interface measurement Procurement • Endress+Hauser being the world market leader in level measurement guarantees asset protection • Worldwide support and service Installation • Special tools are not required •...
  • Page 8: Measuring System

    Levelflex FMP51, FMP52, FMP54 Measuring system General notes on probe selection • Normally use rod or coax probes for liquids. Rope probes are used in liquids for measuring ranges > 10 m (33 ft) ( > 4 m (13 ft) for FMP52) and with restricted ceiling clearance which does not allow the installation of rigid probes.
  • Page 9 Levelflex FMP51, FMP52, FMP54 Levelflex FMP52 Type of probe Rod probe Rope probe A0011357 A0011358 Feature 060 - Probe: Option: Option: 16 mm (PFA>316L) 4 mm (PFA>316), max. 150 mm nozzle height, center rod 0.63 in (PFA>316L) 4 mm (PFA>316), max. 300 mm nozzle height, center rod 1/6"...
  • Page 10: Input

    Levelflex FMP51, FMP52, FMP54 Input Measured variable The measured variable is the distance between the reference point and the product surface. Subject to the empty distance entered "E" the level is calculated. Alternatively, the level can be converted into other variables (volume, mass) by means of linearization (32 points).
  • Page 11: Blocking Distance

    Levelflex FMP51, FMP52, FMP54 • Reduction of the max. possible measuring range through buildup, above all of moist products. • Due to the high diffusion rate of ammonia it is recommended with gas-tight bushing for measurements in this medium. Blocking distance The upper blocking distance (= UB) is the minimum distance from the reference point of the measurement (mounting flange) to the maximum level.
  • Page 12: Signal On Alarm

    Levelflex FMP51, FMP52, FMP54 Signal on alarm Maintenance information can be viewed via the following interfaces: • Local display: – Error symbol (in accordance with NAMUR Recommendation NE 107) – Plain text display • Current output: failsafe mode selectable (in accordance with NAMUR Recommendation NE 43): –...
  • Page 13: Auxiliary Energy

    Levelflex FMP51, FMP52, FMP54 Auxiliary energy Electrical connection 2-wire, 4-20mA HART (FMP5x - **A...) Without intgrated overvoltage protection – – 4...20 mA A0011294 Terminal 4...20mA HART passive Active barrier with power supply (e.g. RN221N): Observe terminal voltage (® ä 16) HART communication resistor (³250 W): Observe maximum load (®...
  • Page 14 Levelflex FMP51, FMP52, FMP54 2-wire, 4-20 mA HART, 4...20mA Without integrated overvoltage protection – – 4...20 mA – – 4...20 mA A0013923 Cable entry for current output 1 Terminal for current output 1 Supply voltage for current output 1 (e.g. RN221N); Observe terminal voltage (® ä 17) HART communication resistor (³...
  • Page 15 Levelflex FMP51, FMP52, FMP54 4-wire, 4-20 mA HART (FMP5x - **K/L...) Without integrated overvoltage protection AC / DC – ³ 4...20 mA A0011340 Terminal 4...20mA HART Evaluation unit, e.g. PLC HART communication resistor (³250 W): Observe maximum load (® ä 18) Analog display device: Observe maximum load (®...
  • Page 16: Supply Voltage

    The HART loop converter HMX50 can be acquired using the order number 71063562. Additional documentation: TI429F and BA371F. Supply voltage An external power supply is required. Various supply units can be ordered from Endress+Hauser: see "Accessories" section (® ä 74) 2-wire, 4-20mA HART, passive "Power Supply, Output" Outputs Terminal voltage "Approval"...
  • Page 17: Terminals

    Levelflex FMP51, FMP52, FMP54 Load (® ä 18) Residual ripple: • < 1 V (0 to 100 Hz) • < 10 mV (100 to 10 000 Hz) 4-wire, 4-20mA HART, active "Power supply; Output" Terminal voltage K: 4-wire 90-253VAC; 4-20mA HART...
  • Page 18: Current Consumption

    Levelflex FMP51, FMP52, FMP54 "Power supply; Output" Power consumption K: 4-wire 90-253VAC; 4-20mA HART 1.5 W (6 VA) L: 4-wire 10,4-48VDC; 4-20mA HART 1.3 W Feature 020 of the product structure Current consumption HART Nominal current 3.6 to 22 mA, the start-up current for multidrop mode can be parametrized (is set to 3.6 mA on delivery)
  • Page 19: Potential Equalization

    • Integrated overvoltage protection (in preparation); Product structure: Feature 610 "Accessory mounted", option NA "Overvoltage protection". • External overvoltage protection, e.g. Endress+Hauser's HAW562Z. When using the external overvoltage protection HAW562Z in explosion hazardous areas observe the associated Safety Instructions XA015R.
  • Page 20: Maximum Measured Error

    Levelflex FMP51, FMP52, FMP54 Maximum measured error Typical data under reference operating conditions: DIN EN 61298-2, percentage values in relation to the span. Output: digital analog Level measurement: Sum of non-linearity, ±0.02 % • Measuring range up to 15 m (49 ft): ±2 mm (0.08 in) nonrepeatability and hysteresis •...
  • Page 21: Resolution

    Levelflex FMP51, FMP52, FMP54 Differing from this, the following measuring error is present in the vicinity of the upper probe end (rod/rope only): 40 mm DC = 2 30 mm DC > 7 20 mm 10 mm 3 mm 0 mm...
  • Page 22: Fmp54 With Gas Phase Compensation

    Levelflex FMP51, FMP52, FMP54 product surface. The following table illustrates this measured error for a few typical gases/vapors (with regard to distance; a positive value means that too large a distance is being measured): Gas layer Temperature Pressure °C °F 1 bar (14.5 psi)
  • Page 23 Levelflex FMP51, FMP52, FMP54 Dref A0014534 Coax probes with reference reflection can be installed in any tank (free in the tank or into a bypass). Coax probes are completely mounted and adjusted ex works. After mounting they are ready for use, additional settings are not necessary.
  • Page 24: Operating Conditions: Installation

    Levelflex FMP51, FMP52, FMP54 Lref = 300 mm Lref = 550 mm 1000 1500 2000 2500 3000 3500 4000 D [mm] A0014535 Distance from liquid surface to lower edge of the flange Delta Measuring error If there are fast changes in pressure, there may be an additional error, since the mesured reference distance is filtered with the time constant of the level measurement.
  • Page 25: Applications With Restricted Mounting Space

    Levelflex FMP51, FMP52, FMP54 Mounting distances • Distance (A) between wall and rod or rope probe: – for smooth metallic walls: > 50 mm (2") – for plastic walls: > 300 mm (12") mm to metallic parts outside the vessel –...
  • Page 26: Notes On The Mechanical Load Of The Probe

    Levelflex FMP51, FMP52, FMP54 • Levelflex version (see product structure): Feature 600 "Probe Design", Option MB "Sensor remote, 3m/9ft cable, detachable+mounting bracket" (® ä 67) • A connecting cable is supplied with this device version – Length: 3 m (9 ft) –...
  • Page 27 Levelflex FMP51, FMP52, FMP54 Sensor Feature 060 Probe Bending strength [Nm] FMP54 AE, AF Rod 16mm (0.63") 316L BA, BB, BC, BD Rod 16mm (0.63") 316L divisible Bending load (torque) through fluid flow The formula for calculating the bending torque M impacting on the probe: ×...
  • Page 28: Notes On The Process Connection

    Levelflex FMP51, FMP52, FMP54 Bending strength of coax probes Sensor Feature 060 Process connection Probe Bending strength [Nm] FMP51 UA, UB Thread G¾ oder NPT¾ Coax 316L, Ø 21,3 • Thread G1½ or NPT1½ Coax 316L, Ø 42,4 • Flange...
  • Page 29 Levelflex FMP51, FMP52, FMP54 Nozzle mounting with flange < ( 6) < Ø < mm (in) Ø < A0015122 For FMP52: Use spring washers in order to ensure electrical contact between the tank and the device flange; see figure below.
  • Page 30: Securing The Probe

    Levelflex FMP51, FMP52, FMP54 Rod extension/centering HMP40 for FMP54 For FMP54 with rope probes the rod extension/centering HMP 40 is available as an accessory (® ä 69). It has to be used if otherwise the probe rope comes into contact with the lower edge of the nozzle.
  • Page 31 Levelflex FMP51, FMP52, FMP54 • The end of the probe needs to be secured under the following conditions: if otherwise the probe sporadically comes into contact with the wall of the vessel, the outlet cone, internal fittings or other parts of the installation.
  • Page 32: Special Mounting Conditions

    Levelflex FMP51, FMP52, FMP54 NOTICE Poor grounding of the end of probe may cause measuring errors. Apply a narrow sleeve which has good electrical contact to the probe. ► NOTICE Welding may damage the electronics. Before welding: Ground the probe and dismount electronics.
  • Page 33 Mounting in a bypass Center washer 3.1 Metallic center washer (316L) for level measurement 3.2 Non-metallic center washer (PEEK, PFA) for interface measurement For information on bypass solutions from Endress+Hauser please contact your Endress+Hauser sales representative. Feature 610 - Accessory mounted Center washer...
  • Page 34 Levelflex FMP51, FMP52, FMP54 Underground tanks A0014142 Use a coax probe for nozzles with large diameters in order to avoid reflections at the nozzle wall. Installation at an angle A0014145 • For mechanical reasons, the probe should be installed as vertically as possible.
  • Page 35 Levelflex FMP51, FMP52, FMP54 Non-metallic vessels A0012527 Non-metallic vessel Metal sheet or metal flange To measure, Levelflex with a rod probe needs a metallic surface at the process connection. Therefore: • Select an instrument version with metal flange (minimum size DN50/2").
  • Page 36 Levelflex FMP51, FMP52, FMP54 Mounting conditions: • The probe must be mounted directly to the tank wall (no open space) • A plastic half pipe with a diameter of approx. 200 mm (8"), or some other protective unit, must be affixed externally to the probe to prevent any influences on the measurement.
  • Page 37 FMP51 and FMP54 are a perfect replacement for a conventional displacer system in an existing displacer chamber. Endress+Hauser offers flanges that suit Fischer and Masoneilan displacer chamber for this purpose (special product for FMP51; feature 100, options LNJ, LPJ, LQJ for FMP54). Thanks to menu-guided local operation, commissioning the Levelflex only takes a few minutes.
  • Page 38 Levelflex FMP51, FMP52, FMP54 A0014153 Flange of the displacer chamber Planning instructions: • In normal cases, use a rod probe. When installing into a metallic displacer chamber up to 150 mm, you have all the advantages of a coax probe.
  • Page 39: Operating Conditions: Environment

    Levelflex FMP51, FMP52, FMP54 Operating conditions: Environment Ambient temperature range Measuring device –40 to +80 °C (–40 to +176 °F) Local display –20 to +70 °C (–4 to +158 °F), the readability of the display may be impaired at temperatures outside the temperature range.
  • Page 40 Levelflex FMP51, FMP52, FMP54 Temperature derating for FMP51 with threaded connection G1½ or NPT1½ [°C] ([°F]) T a +80 (+176) GT20: +57 (+135) GT18: +49 (+120) 4 20 mA HART – GT19: +20 (+68) -40 (-40) [°C] +200 ([°F]) (-40)
  • Page 41 Levelflex FMP51, FMP52, FMP54 Temperature derating for FMP52 [°C] ([°F]) T a +80 (+176) GT20: +60 (+140) GT18: +53 (+127) GT19: +38 (+100) 4 20 mA HART – GT19: -36 (-33) GT18: -37 (-35) GT20: -38 (-36) -40 (-40) [°C]...
  • Page 42: Storage Temperature

    Levelflex FMP51, FMP52, FMP54 Temperature derating for FMP54 - Variante HT bis +450 °C (+842 °F ) [°C] ([°F]) T a +80 (+176) GT20: +56 (+133) GT18: +54 (+129) GT19: +42 (+108) 4 20 mA HART – GT19: -22 (-8)
  • Page 43: Operating Conditions: Process

    Levelflex FMP51, FMP52, FMP54 When installing the probes in metal and concrete tanks and when using a coax probe: • Interference emission to EN 61326 - x series, electrical equipment Class B. • Interference immunity to EN 61326 - x series, requirements for industrial areas and NAMUR...
  • Page 44: Materials In Contact With Process

    • ASME B 16.5a - 1998 Tab. 2.3.8 N10276 • JIS B 2220 Materials in contact with • Endress+Hauser supplies DIN/EN flanges and threaded process connections made of stainless steel process according to AISI 316L (DIN/EN material number 1.4404 or 1.4435). With regard to their temperature stability properties, the materials 1.4404 and 1.4435 are grouped under 13E0 in EN 1092-1 Tab.
  • Page 45 Levelflex FMP51, FMP52, FMP54 Levelflex FMP52 Flange Dairy coupling Tri-Clamp No. Material EN/ASME/JIS DN50 (DIN 11851) 3" 2" 1½" Coating 2 mm (0.08 in): PTFE (Dyneon TFM1600) 304L (1.4307) Levelflex FMP54 Threaded connection G1½, NPT1½ Flange No. Material Variante HT...
  • Page 46 Levelflex FMP51, FMP52, FMP54 Levelflex FMP51 Rod probe No. Material Æ 16 mm (2/3") Æ 12 mm (1/2") divisible 316L (1.4404) Connecting bolt: 1.4462, Duplex CR22 Nordlock washer: 1.4547 Hexagon head screw: A4-70 Nordlock washer: 1.4547 A0013860 A0013861 Levelflex FMP52...
  • Page 47: Dielectric Constant (Dc)

    Levelflex FMP51, FMP52, FMP54 Levelflex FMP54 Rope probe Rod probe Æ 4 mm (1/6") Æ 16 mm (2/3") Coax probe No. Material Æ 16 mm Æ 16 mm (2/3") Æ 4 mm (1/6") with centering with centering (2/3") divisible disk disk 316L (1.4404)
  • Page 48: Mechanical Construction

    Levelflex FMP51, FMP52, FMP54 Mechanical construction Design, dimensions Dimensions of the electronics housing 90 (3.54) 78 (3.07) A0015132 å 8 Housing GT18 (316L); Dimensions in mm (in) 78 (3.07) 90 (3.54) A0015133 å 9 Housing GT19 (Plastics PBT); Dimensions in mm (in) 90 (3.54)
  • Page 49 Levelflex FMP51, FMP52, FMP54 FMP51: Dimensions of process connection (G¾,NPT¾) and probe (4.8) = 100 (4) ø82.5 ø59.35 (ø3.25) (ø2.34) SW36 AF36 ¾ NPT¾ ø10 (0.4) ø4 ø4 ø8 ø22 (ø0.16) (ø0.16) (ø0.31) (ø .87) 2 (0.08) ø29 (ø1.14) ø22 (ø...
  • Page 50 Levelflex FMP51, FMP52, FMP54 FMP51: Dimensions of process connection (G1½,NPT1½,flange) and probe (4.8) = 100 (4) ø59.35 ø59.35 ø59.35 (ø2.34) (ø2.34) (ø2.34) ø82.5 SW55 SW55 (ø3.25) AF55 AF55 ½ ½ SW10 SW14 AF10 ø10 (0.4) AF14 SW10 AF10 ø16 SW10 (ø0.63)
  • Page 51 Levelflex FMP51, FMP52, FMP54 FMP52: Dimensions of process connection and probe (4.8) = 100 (4) ø82.5 (ø3.25) ø59.8 (ø2.35) ø59.8 ø68.5 ø63.9 ø90.89 (ø2.35) (ø 2.7) (ø 2.52) (ø 3.58) ø16 ø16 ø16 ø16 ø16 (ø 0.63) (ø 0.63) (ø...
  • Page 52 Levelflex FMP51, FMP52, FMP54 FMP54: Dimensions of process connection and probe (4.8) = 100 (4) SW60 SW60 AF60 AF60 ø82.5 (ø3.25) ø90 ø90 ø90 ø90 (ø3.54) (ø3.54) (ø3.54) (ø3.54) SW14 SW14 SW14 AF14 AF14 SW14 AF14 AF14 M40x1 M40x1 M40x1 M40x1 ø16...
  • Page 53: Tolerance Of Probe Length

    Levelflex FMP51, FMP52, FMP54 Tolerance of probe length Rod probes Over [m (ft)] — 1 (3,3) 3 (9,8) 6 (20) Up to [m (ft)] 1 (3,3) 3 (9,8) 6 (20) — Admissible tolerance [mm (in)] -5 (-0,2) -10 (-0,39) -20 (-0,79)
  • Page 54: Materials

    Levelflex FMP51, FMP52, FMP54 Materials A0013788 Housing GT18 - stainless steel, corrosion-resistant No. Part: material No. Part: material Housing: 316L (CF-3M, 1.4404) Cable entry • Sealing: EMPB 2.1 Cover of the electronics compartment • Cable gland: 316L (1.4404) • Cover: 316L (CF-3M, 1.4404) •...
  • Page 55 Levelflex FMP51, FMP52, FMP54 Housing GT20 - die-cast aluminum, powder-coated, seawater-resistant No. Part: material No. Part: material Housing: AlSi10Mg(<0.1% Cu) Cable entry • Sealing: EMPB 2.1 Cover of the electronics compartment • Cable gland: polyamide (PA), nickel-plated brass (CuZn) • Cover: AlSi10Mg(<0.1% Cu) •...
  • Page 56: Human Interface

    On-site operation options Display module SD02, push buttons; cover must be open for operation Operating options via CDI interface (= Endress+Hauser Common Data Interface) 2.1 Computer with operating tool (FieldCare) 2.2 Commubox FXA291, connected to the CDI interface of the device...
  • Page 57: Remote Operation

    Levelflex FMP51, FMP52, FMP54 Remote operation Operation via: • HART protocol • Operating tools – FieldCare (® ä 73) – AMS Device Manager – SIMATIC PDM A0013764 å 12 Options for remote operation via HART protocol PLC (programmable logic controller) Transmitter power supply unit, e.g.
  • Page 58: System Integration

    System integration Integrated in tank gauging system The Endress+Hauser Tank Side Monitor NRF590 provides integrated communications for sites with multiple tanks, each with one or more sensors on the tank, such as radar, spot or average temperature, capacitive probe for water detection and/or pressure sensors. Multiple protocols out of the Tank Side Monitor guarantee connectivity to nearly any of the existing industry standard tank gauging protocols.
  • Page 59 The number of instruments which can be connected in mutidrop mode can be calculated by the "FieldNetCalc" program. A description of this program can be found in Technical Information TI 400F (Multidrop Conncector FXN520). The program is available form your Endress+Hauser sales organisation or in the internet at: www.de.endress.com/Download...
  • Page 60: Certificates And Approvals

    The measuring system meets the legal requirements of the applicable EC guidelines. These are listed in the corresponding EC Declaration of Conformity together with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. C-Tick symbol The measuring system meets the EMC requirements of the "Australian Communications and Media Authority...
  • Page 61: Ordering Information

    Levelflex FMP51, FMP52, FMP54 • NAMUR NE 53 Software of field devices and signal-processing devices with digital electronics • NAMUR NE 107 Status classification as per NE107 • NAMUR NE 131 Requirements for field devices for standard applications • IEC61508...
  • Page 62 Levelflex FMP51, FMP52, FMP54 Approval: 51 52 54 ATEX II 1/2G Ex ia IIC T6, 1/2D Ex tD IIIC IP6x ATEX II 1/2G Ex d(ia) IIC T6, 1/2D Ex tD IIIC IP6x ATEX II 1/2G Ex ia IIC T6, Ex d(ia) IIC T6 CSA General Purpose CSA C/US DIP Cl.II,III Div.1 Gr.E-G...
  • Page 63 Levelflex FMP51, FMP52, FMP54 Electrical connection: 51 52 54 Gland M20, IP66/68 NEMA4X/6P Thread M20, IP66/68 NEMA4X/6P Thread G1/2, IP66/68 NEMA4X/6P Thread NPT1/2, IP66/68 NEMA4X/6P Plug M12, IP66/68 NEMA4X/6P Plug 7/8", IP66/68 NEMA4X/6P Special version, TSP-no. to be sepc. Probe: 51 52 54 ..
  • Page 64 Levelflex FMP51, FMP52, FMP54 Seal: 51 52 54 Graphite, -196...450°C (HT) Special version, TSP-no. to be sepc. Process connection: 51 52 54 2" 300/600lbs RF, 316/316L flange ANSI B16.5 3" 300/600lbs RF, 316/316L flange ANSI B16.5 1-1/2" 150lbs RF, 316/316L flange ANSI B16.5 1-1/2"...
  • Page 65 Levelflex FMP51, FMP52, FMP54 Process connection: 51 52 54 DN100 PN10/16 B1, 316L flange EN1092-1 CHK DN100 PN10/16, PTFE>316L flange EN1092-1 CHM DN100 PN10/16, AlloyC>316L flange EN1092-1 DN150 PN10/16 B1, 316L flange EN1092-1 DN150 PN10/16, PTFE>316L flange EN1092-1 DN200 PN16 B1, 316L flange EN1092-1 DN40 PN10-40 B1, 316L flange EN1092-1 CQK DN40 PN10-40, PTFE>316L flange EN1092-1...
  • Page 66 Levelflex FMP51, FMP52, FMP54 Process connection: 51 52 54 DN100 PN100 B2, 316L flange EN1092-1 Thread ANSI MNPT1-1/2, 200bar, 316L Thread ANSI MNPT1-1/2, 400bar, 316L Thread ANSI MNPT3/4, 316L Thread ANSI MNPT1-1/2, 316L Tri-Clamp ISO2852 DN40-51 (2"), 3A, EHEDG, PTFE>316L Tri-Clamp ISO2852 DN40-51 (2"), PTFE>316L...
  • Page 67 Levelflex FMP51, FMP52, FMP54 Test, Certificate: (Multiple options can be selected) 51 52 54 EN10204-3.1 material wetted parts 316/ 316L, inspection certificate EN10204-3.1 material pressurized 316/316L, inspection certificate NACE MR0103/MR0175 wetted parts EN10204-3.1 Helium leackage test, inspection certificate EN10204-3.1 pressure test, inspection certificate EN10204-3.1 PMI test, x-ray fluorescence spectroscopy, inspection certificate...
  • Page 68 Levelflex FMP51, FMP52, FMP54 5 point linearity protocol The following notes must be taken into account if option F4 ("5 point linearity protocol") has been selected in feature 550 ("Calibration"). The five points of the linearity protocol are evenly distributetd throughout the measuring range (0% to 100%).
  • Page 69: Accessories

    Levelflex FMP51, FMP52, FMP54 Customized parametrization If the option IJ "Customized parametrization HART" has been selected in feature 570 "Service", customer specific presettings can be selected for the following parameters: Parameter Communication Selection list / range of values Setup ® Distance unit HART •...
  • Page 70 Levelflex FMP51, FMP52, FMP54 Accessory Description 215mm; 250-350mm / 10-14" 315mm; 350-450mm / 14-18" 415mm; 450-550mm / 18-22" Special version, TSP-no. to be spec. Center washer: Not selected DN40 / 1-1/2", inside-d. = 40-45mm, PPS DN50 / 2", inside-d. = 50-57mm, PPS DN80 / 3", inside-d.
  • Page 71 Levelflex FMP51, FMP52, FMP54 Accessory Description Mounting kit, isolated A0013586 Insulating sleeve Eye-bolt For reliably insulated fixing of the probe. Maximum process temperature: 150 °C (300 °F) For rope probes 4 mm (1/6 in) or 6 mm (1/4 in) with PA>steel: •...
  • Page 72 Levelflex FMP51, FMP52, FMP54 Accessory Description Centering disk PEEK Æ 48 to 95 mm 10 (0.39) (1.89 to 3.74 inch) can be used for • FMP51 • FMP54 Ø 48 (1.89) Ø 75 (2.95) Ø 95 (3.74) mm (in) A0014576 The centering disk is suitable for probes with a rod diameter of Ø...
  • Page 73: Communication-Specific Accessories

    For intrinsically safe HART communication with FieldCare via the USB interface. For details refer to Technical Information TI404F/00 Accessory Description Commubox FXA291 Connects Endress+Hauser field devices with CDI interface (= Endress+Hauser Common Data Interface) to the USB interface of a computer. For details refer to Technical Information TI405C/07 Accessory Description...
  • Page 74: System Components

    Standard documentation The following document types are available: • On the CD supplied with the device • In the Download Area of the Endress+Hauser Internet site: www.endress.com ® Download Levelflex FMP51, FMP52, FMP54 Correlation of documentations to the device: Device...
  • Page 75: Certificates

    Levelflex FMP51, FMP52, FMP54 Certificates Safety Instructions (XA) for Levelflex FMP51, FMP52, FMP54 Depending on the approval, the following Safety Instructions (XA) are supplied with the instrument. They are an integral part of the Operating Instructions. 51 52 54 Feature 010...
  • Page 76 1 301 914 6.559.657 1 020 735 6.640.628 6.691.570 6.847.214 7.441.454 7.477.059 1 389 337 Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com *71120833* TI01001F/00/EN/10.10...

This manual is also suitable for:

Levelflex fmp52Levelflex fmp54

Table of Contents