Make sure that the positive (+) end and negative (—)
end of the wire are connected to the same signs on the
terminal
Use a DC cable with a nominal cross section of 1 25
mm? or more that meets the UL specifications
Terminal Board LAMP CONTROL (Wire (2)
Connect it only in case of supplving power from LAMP
AC OUT on the Panftilt Head AC Adapter AW-PS300 to
the halogen lamp
Connect it to LAMP CONTROL on the Panftilt Head AC
Adapter
The svmbols C and S of the wire must match the same
symbols on the-terminal
|
Use a cable with a nominal cross section of 0 3 mm'or
more that meets the UL specifications
Terminal Board OP (Wire @)
Connect it only in case of using OP SW CONTROL.
OUT on the Panftilt Head AC Adapter AW-PS300
Connect it to OPTION SW CONTROL IN on the Pan/tilt
Head AC Adapter
Use a cable with a.nominal cross.section of 0 3 mm? or
more that meets the UL specitications