Holiday Occupancy Schedules - TCS SuperSTAT Series Configuration Manual

Communicating thermostat
Hide thumbs Also See for SuperSTAT Series:
Table of Contents

Advertisement

Configuration

Holiday Occupancy Schedules

The SuperSTAT has two separate holiday occupancy groups (Holiday #1 and Holiday #2). Within each occupancy group
you can assign up to four occupancy time periods (A – D). After programming the occupancy time periods, you can then
assign them to multiple holidays. You can also configure the duration for each holiday schedule (in days).
STEP 1
Set Occupied Times Holiday No. 1: This screen indicates that
the occupancy time periods for the first holiday group are
ready to be configured. Press the CLOCK SETUP button on the
keypad to advance to the setup screens for the holiday group.
STEP 2
Copy Sunday For Holiday 1: Holiday 1 gives you the option
of copying the schedule from the previous Sunday. If you
select YES, the occupancy time periods from the previous
day (Sunday) will be copied and you will skip to Step 4. If you
select NO, screens for Occupancy Periods A – D (not shown)
will appear. As with the occupancy time periods for regular
days, You can enter up to four different occupancy time
periods.
STEP 3
Set Occupied Times Holiday No. 2: This screen indicates that
the occupancy times for second holiday group are ready to
be configured. Press the CLOCK SETUP button on the keypad
to advance to the setup screens for the holiday group.
STEP 4
Occupancy Time Periods (1 of 2): Holiday 2 does not give
you the opportunity to copy occupancy time periods from a
regular day. Set hours and minutes (military time) for start
and stop times for occupancy periods A and B.
NOTE:
Occupancy time periods with start and end times of
00:00 are inactive.
STEP 5
Occupancy Time Periods (2 of 2): Set hours and minutes
(military time) for start and stop times for occupancy periods
C and D.
STEP 6
Holiday Group 1 Dates: This screen indicates that the Holiday
1 occupancy time periods are ready to be assigned to
specific dates. Press the CLOCK SETUP button on the keypad
to advance to the setup screens for the holiday group.
STEP 7
Holiday Group 1 Dates: In this screen, you can assign the
Holiday 1 occupancy time periods to as many as 12 holidays.
Enter the two-digit month, date, and duration in days. To add
additional dates to this group, press the OVERRIDE button.
Press the WARMER button to advance the Date number and
add additional months and dates.
STEP 8
Holiday Group 2 Dates: This screen indicates that the
Holiday 1 occupancy time periods are ready to be assigned
to specific holidays. Press the CLOCK SETUP button on
the keypad to advance to the setup screens for the holiday
group.
12
2800 Laura Lane
Middleton, WI 53562
SET OCCUPIED
TIMES HOLIDAY #1
COPY SUN FOR
HOL#1?
SET OCCUPIED
TIMES HOLIDAY #2
A:08:00 TO 17:00
B:00:00 TO 00:00
C:00:00 TO 00:00
D:00:00 TO 00:00
ENTER DATES FOR
HOLIDAY #1:
HOL1
DURATION=00 DAYS
ENTER DATES FOR
HOLIDAY #2:
|
800.288.9383
|
www.tcsbasys.com
NO
01=00=00

Advertisement

Table of Contents
loading

This manual is also suitable for:

Superstat sz1041

Table of Contents