Clearing Memory Of Accessories; Toggle Enable/Disable Stb-Triggered Work Light Features - Genie GCL-LT Manual

Light-duty trolley operator for sectional doors
Table of Contents

Advertisement

SPECIAL INSTALLATION INFORMATION

CLEARING MEMORY OF ACCESSORIES

NOTE: Clearing memory of remotes from the operator
will clear ALL programmed remotes, wireless keypads
and vehicle transmitters. The operator will no longer
recognize any signal from any remote device, including
a missing remote device. This does not include the
Aladdin Connect® or Wireless Wall Console.
All remotes, vehicles and wireless keypads MUST be
reprogrammed.
1. Press and hold the SET/PRGM button on
the operator for two seconds.
· The ROUND LED will turn BLUE.
· The ROUND LED will then flash PURPLE.
2. Press and hold the UP & DOWN buttons at
the same time until both LEDs turn off.
· Both operator LEDs will flash and turn
off indicating that all remotes have been
erased.
3. Press any remote button.
· The operator should NOT run.
To deprogram the same remote for other garage
door operators, repeat the steps above using one
of the other remaining remote buttons.

TOGGLE ENABLE/DISABLE STB-TRIGGERED WORK LIGHT FEATURES

1. Remove power from the operator
2. Press & hold the UP arrow "+"
3. Continue to hold the UP arrow "+" and apply power to the operator.
4. Observe the light flash and release the UP arrow "+" button and test.
NOTE:
To test this feature the door must be cycled to the open position and
then allow the light to turn off after 4 min.
34
1. Enter Programming Mode
Solid Blue
PRGM
SET
Flashing
PRGM
Purple
SET
2. Press and Hold + & - Buttons
PRGM
SET
Flashing
Blue
3. Test Remote
Release when
LEDs turn off