Genie GCL-LT Manual

Light-duty trolley operator for sectional doors
Table of Contents

Advertisement

Quick Links

GCL-LT
Light
Light-Duty Trolley Operator
- Duty Operator
for Sectional Doors
Models: OPGLDT0011
OPGLDT0011W
OPGLDT0011WB
Light - Duty Trolley Operator
SAFETY & STANDARD FEATURES
2
APPLICATIONS:
For use only on the following types of doors:
• Sectional Doors - Standard Lift
1. Safe-T-Beam® (STB) Non-Contact Reversing System:
Door maximum weight / height:
• Places an infrared beam across the door opening.
• 750 lbs. / 14 ft.
• Only affects the DOWN travel of the door.
• Stops an open door from closing or reverses a door while in the down travel.
UL 325 Listed for residential and commercial applications
• Reversing system can be overridden with constant pressure on the wired wall console only.
• The door will stop and reverse to the full open position if beam is obstructed.
• Self-diagnostic LEDs on STBs and Powerhead alert to operational issues (See Locating Safe-T-Beam® Pairs &
The included Safe-T-Beam ® system, or other monitored safety device UL 325 Listed for use on this model,
Troubleshooting section in this manual for more information).
MUST be installed to close the door. DO NOT use other brands or types of monitored entrapment.
2. Contact Reversing System:
• Automatically reverses a closing door upon contact with an obstruction (Force Control)
3. Manual Emergency Release pull handle & cord:
• Manually releases door from door opener. Used during a power failure or other emergency to allow manual
opening and closing of the door.
This installation manual provides the information required to install,
• DO NOT use emergency release cord to pull the door!
program, troubleshoot and maintain a GCL-LT operator.
4. Automatic Lighting System:
• Lighting system turns ON when door is activated and automatically turns OFF 4 minutes later.
• Can be activated/deactivated manually from the wall console.
5. Genie Battery Backup (BBU):
SERIAL NUMBER DECAL
• Included or optional with select models. Provides power to opener in the event of a power failure. DO NOT
install BBU until opener is fully installed, programmed and tested.
6. Integrated Aladdin Connect® (iDCM):
113228.01077
• Available with select models, allows operation of the garage door opener with a secure mobile device
application (app) from anywhere.
4
5
6
7
8
3
2
1
Cycle Rating:
8 cycles/hour maximum up to 25 cycles/day
Vehicle
Compatible
PLACE iDCM SERIAL NUMBER DECAL HERE IF Optional
iDCM KIT IS INSTALLED
12/2022

Advertisement

Table of Contents
loading

Summary of Contents for Genie GCL-LT

  • Page 1 This installation manual provides the information required to install, • DO NOT use emergency release cord to pull the door! program, troubleshoot and maintain a GCL-LT operator. 4. Automatic Lighting System: • Lighting system turns ON when door is activated and automatically turns OFF 4 minutes later.
  • Page 2: Table Of Contents

    INDEX Special Installation Information:...... 33 General Information & Instructions:....1 Changing Force Settings ......... 33 Safety & General Information: Clearing Memory of Accessories ......34 Safety Information and Instructions ....1-4 Toggle Enable/Disable STB-Triggered Important Installation Instructions ......5 ............34 Work Light Features Approved Safety Devices ...........6 Adjusting Speed Control ........
  • Page 3: General Information & Instructions

    GENERAL INFORMATION AND INSTRUCTIONS SAFETY INFORMATION AND INSTRUCTIONS Job Site Considerations The following list of items should be evaluated prior to selecting an operator for a given job site. 1. Available 120 VAC 1A power source. 2. Type of door. 3.
  • Page 4 If you have any questions or do not understand the information presented, call your nearest service representative. For the number of your local Genie Dealer at 1-800-OK-GENIE In this manual the words Danger, Warning, and Caution are used to stress important safety information.
  • Page 5 Si vous avez des questions ou si vous ne comprenez pas les informations ci-incluses, veuillez contacter le représentant de service le plus près. Pour obtenir le numéro du revendeur Genie local, appelez le +1 (800)-OK-GENIE. Dans ce manuel, les mots Danger, Avertissement, et Attention sont utilisés pour faire ressortir d’importantes informations relatives à...
  • Page 6 • Lighting system turns ON when door is activated and automatically turns OFF 4 minutes later. • Light can be activated/deactivated manually from the wall console. 5. Genie Battery Backup (BBU): • Included or optional with select models. Provides power to operator in the event of a power failure. DO NOT connect BBU until operator is fully installed, programmed and tested.
  • Page 7: Important Installation Instructions

    SAFETY INFORMATION AND INSTRUCTIONS IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk of severe injury or death: 1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 2. Install only on a properly operating and balanced garage door. An improperly balanced door has the potential to inflict severe injury.
  • Page 8: Approved Safety Devices

    Monitored Light Curtains (Powered with Transformer 36238A) OPAKMLC3.S KIT,LIGHT CURTAIN,3FT OPAKMLC6.S KIT,LIGHT CURTAIN,6FT DC/T3 Monitored Edge Interface Adapter (Commercial Applications Only) OPAKMEIGX.S KIT,MONITORED EDGE X-SERIES Genie Wireless Edge Kit (Powered with Transformer (36238A) (Commercial Applications Only) OPAKRWET2.S KIT,XMTR/RCVR,SENSING EDGE,WIRELESS,T2 KIT,XMTR/RCVR,w/CONVERTER,SENSING EDGE,WIRELESS,T3 OPAKRWET3.S...
  • Page 9: Assembly & Installation Of Operator

    While going over these instructions, please note the additional items you may need. For help finding a local Genie® Professional Dealer, refer to the dealer locator at www.GenieCompany.com or call Customer Service at 1-800-35-GENIE.
  • Page 10: Assemble Operator

    ASSEMBLE OPERATOR A = Operator assembly B = Battery backup (BBU) C = Wall console control D = Lens cover E = Curved door arm F = Photocell kit G = Rail assembly H = Parts Bag I = Parts Bag UNPACK, INVENTORY, AND INSPECT ALL PARTS &...
  • Page 11: Install Header Bracket

    INSTALL HEADER BRACKET SECTIONAL DOORS Mark Door Centerline 1. Measure the width of the door to determine the center. 2. Place a mark on the top of the door and the header above the door to indicate the DOOR CENTERLINE FIG. 2. CENTERLINE.
  • Page 12: Install Operator Rail To Header Bracket

    INSTALL OPERATOR TO RAIL HEADER BRACKET 1. Slide clevis pin through holes in rail and bracket and secure with spring clip. FIG. 5. 2. Disengage the carriage by pulling the release handle down, toward the door and then releasing 3. Slide carriage/straight door arm near the operator now to prevent Chain/Belt Drive damage to the door for the next step.
  • Page 13: Mount Operator To The Ceiling

    MOUNT OPERATOR TO CEILING Method A For open ceilings with exposed joist, drill 5/32” pilot holes and secure PERFORATED HANGING STRAPS (NOT- included) to joist using 5/16” x 1-3/4” lag screws. Raise operator unit so that there is sufficient clearance between door and rail.
  • Page 14: Attach Bracket And Drawbar Arm To Door

    Note: Some garage door manufacturers provide door brackets that CAN be used with your Genie Door Arms. In some cases, a garage door operator reinforcement bracket should be used. Check the recommendations from the door manufacturer. Attach door bracket to reinforcement bracket.
  • Page 15 ATTACH BRACKET AND DRAWBAR ARM TO DOOR 1. Slide the carriage to about 16 inches from the door. 2. Position carriage and door arms to form an angle of approximately 20 to 30 degrees. FIG. 10. 3. Attach the curved and straight door arms together using 3/8"-16 x 7/8" bolts and nuts. Place fasteners as close to the end as possible of both the curved and straight door arm.
  • Page 16: Wire Operator, Install & Wire Accessories

    WIRE OPERATOR, INSTALL & WIRE ACCESSORIES TOOLS REQUIRED & TYPICAL INSTALLATION TOOLS: Ladder, Pencil, Small Common Screwdriver, Wire Strippers/Wire Cutters, Hammer, 3/32” Drill, 1/4” Socket/Ratchet NOTICE: All low voltage wiring must be CL2 fire rated or equivalent. TYPICAL INSTALLATION Wall mount Photocell 6 ”...
  • Page 17: Install And Wire Wired Wall Console

    INSTALL AND WIRE WIRED WALL CONSOLE CAUTION CAUTION Lorsque vous utilisez des agrafes isolées, assurez-vous qu’ e lles sont suffisamment serrées pour maintenir When using insulated staples, make only snug enough to hold electrical wire in place. Staples too tight can le fil électrique en place.
  • Page 18: Install And Wire Monitored Safety Device

    INSTALL AND WIRE MONITORED SAFETY DEVICE Installing Safe-T-Beams® on multiple garage doors (Preventing “cross-talk”) LOCATING SAFE-T-BEAM® PAIRS Multiple Garage Doors LOCATING SAFE-T-BEAM® PAIRS Transmitter (RED LED) and Receiver (GREEN LED) • NEVER position Safe-T-Beam® modules where Transmitter (RED LED) and Receiver (GREEN LED) signals will cross.
  • Page 19: Wired Nema 4X Photocells (Optional)

    INSTALL AND WIRE MONITORED SAFETY DEVICE Wired NEMA 4X Photocells (Optional) 1. Fully close door. 2. Determine photocell location under the following considerations: • As near door opening as possible. • With an unobstructed path between photocells. • Extended from the wall so that door hardware will not obstruct beam. •...
  • Page 20: Wired Monitored Light Curtain (Optional)

    INSTALL AND WIRE MONITORED SAFETY DEVICE Wired Monitored Light Curtain (Optional) WARNING Actuating the operator by using constant contact on the CLOSE button will override non-functioning external reversing devices, including sensing edges. AVERTISSEMENT L’activation de l’operateur en util isant un contact constant sur le bouton FERMER annulera les dispositifs d’inversions externes, y compris les systèmes de détection des bords.
  • Page 21: Wired Safety Edge Instructions (Optional)

    INSTALL AND WIRE MONITORED SAFETY DEVICE Wired Safety Edge Instructions (Optional) WARNING Actuating the operator by using constant contact on the CLOSE button will override non-functioning external reversing devices, including sensing edges. AVERTISSEMENT L’activation de l’operateur en util isant un contact constant sur le bouton FERMER annulera les dispositifs d’inversions externes, y compris les systèmes de détection des bords.
  • Page 22: Wireless Monitored Safety Edge (Optional)

    INSTALL AND WIRE MONITORED SAFETY DEVICE Wireless Monitored Safety Edge (Optional) WARNING Actuating the operator by using constant contact on the CLOSE button will override non-functioning external reversing devices, including sensing edges. AVERTISSEMENT L’activation de l’operateur en util isant un contact constant sur le bouton FERMER annulera les dispositifs d’inversions externes, y compris les systèmes de détection des bords.
  • Page 23: Install Light Bulbs And Lens Cover

    INSTALL LIGHT BULBS AND LENS COVER * Genie LED light bulbs are designed to reduce or eliminate reduced remote range issues caused by common LED bulbs. They also offer better product life by making them resistant to vibration caused by the operator, and cold or damp weather.
  • Page 24: Installing Battery Backup (Optional)

    NeedÊhelpÊorÊhaveÊquestions?Ê B. Do not install Battery Back-up unit on an improperly balanced Ê DOÊNOTÊRETURNÊtoÊtheÊstore.Ê door. An unbalanced door could cause severe injury or damage to this unit. Repairs and adjustments to the door must be made by CallÊus:Ê800-354-3643Ê INSTALLING BATTERY BACKUP (OPTIONAL) trained service persons using proper tools and instructions.
  • Page 25: Apply Power To Operator

    APPLY POWER TO OPERATOR CAUTION DO NOT run operator until travel limits have been set to avoid damage to unit. CAUTION NE PAS faire fonctionner l’ o uvre-porte au-delà des limites de parcours pour ne pas endommager l’unité. WARNING Operator is equipped with grounded electrical plug for your protection, and only fits grounded electrical outlets.
  • Page 26: Programming Operator And Accessories

    PROGRAMMING OPERATOR AND ACCESSORIES NOTE: Before programming the operator, check to make sure there are no objects in the garage door opening. DO NOT allow persons to enter the area of the door while programming and operating. The following steps list the order of programming the operator’s functional settings and install any accessories that were included with the operator or purchased separately.
  • Page 27: Down Travel Limit

    La tendeur DOIT être engagée dans le chariot AVANT de régler les limites. Voir le poster d’installation (si fourni) ou appelez le service clientèle au 1-800-35-GENIE ou visitez le site www.geniecompany.com. • NE PAS fixer de limites en mode batterie de secours. L’alimentation CA DOIT être branchée sur l’ouvre-porte, pendant le réglage des limites,...
  • Page 28: Up Travel Limit

    PROGRAMMING UP TRAVEL LIMIT Programming UP Limit: 1-2. Enter Programming Mode HOLD 1. Press and hold the UP arrow button. UNTIL · Long LED will light BLUE. Steady Blue PRGM 2. Release UP arrow button. Lights · Round LED will flash BLUE. Flashing PRGM Blue...
  • Page 29: Force Control Adjustments

    Force Control Adjustments: The force controls are automatically set when the wall control is used for the first time with garage door operator. The door MUST complete one full cycle, from full open to full close and then, full close to full open, before the settings are automatically recorded.
  • Page 30: Transmitter Programming (If Applicable)

    TRANSMITTER PROGRAMMING (IF APPLICABLE) NOTE: Each programming step has a 30 second time 1. Activate Remote limit for completion after the function is initiated. After 30 seconds, two LED’s will illuminate RED indicating time has expired and the step must be re-started. Restart the step as many times as necessary to complete the programming.
  • Page 31: Wireless Keypad (If Applicable)

    • Choose the button on the HomeLink that will be used to open the door. • Hold down the Genie remote button. While holding, press and hold the chosen HomeLink button. • Hold down both buttons until the indicator on the HomeLink blinks slow then fast. Once it blinks, release both buttons.
  • Page 32: Wireless Wall Console (If Applicable)

    WIRELESS WALL CONSOLE PROGRAMMING (IF APPLICABLE) Please see complete instructions that accompany Wireless Wall Console. Open cover & remove battery tab prior to Battery Tab programming. STEP 1) Program Wall Console to Garage Door Operator 1. Press and hold the program button on the operator until the round LED turns blue, then release.
  • Page 33: Integrated Aladdin Connect (If Applicable)

    • Operator light system and an audible signal will activate as a warning that the operator is about to operate. To use the Genie Aladdin Connect® app to control this garage door system follow these steps. Other home automation apps may also control this garage door operator system.
  • Page 34: Connect Battery Backup To Operator

    STEP 3) Follow the Aladdin Connect® app instructions Follow steps per the app instructions. For help at any time contact The Genie Company at NOTA: Si no funciona el abridor, vuelva a comprobar las conexiones Method 2 - Angle Iron Mount...
  • Page 35: Special Installation Information

    SPECIAL INSTALLATION INFORMATION Changing Force Settings WARNING AVERTISSEMENT Pour éviter les blessures ou des dommages TO AVOID INJURY OR DAMAGE • NE JAMAIS régler la force pour compenser des • NEVER adjust the force settings to adjust for damage, dommages, y compris une porte mal équilibrée, un rail including an unbalanced door, binding door track or de porte coinçant ou des ressorts cassés.
  • Page 36: Clearing Memory Of Accessories

    SPECIAL INSTALLATION INFORMATION CLEARING MEMORY OF ACCESSORIES 1. Enter Programming Mode NOTE: Clearing memory of remotes from the operator will clear ALL programmed remotes, wireless keypads Solid Blue PRGM and vehicle transmitters. The operator will no longer recognize any signal from any remote device, including a missing remote device.
  • Page 37: Adjusting Speed Control

    SPECIAL INSTALLATION INFORMATION Adjusting Speed Control 1-3. Enter Speed Control Mode Speed Settings (DC Models only) Speed settings are pre-programmed at the factory for the maximum PRGM speed. Speed settings should not need adjustment with this unit. However, travel speed for the operator can be adjusted to a slower BLUE speed in both the Open and Close directions, to minimize wear on PRGM...
  • Page 38: Maintenance

    MAINTENANCE IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of severe injury or death, read and follow all instructions. 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with door controls. Keep the remote control away from children. 3.
  • Page 39: Door Inspection

    MAINTENANCE Regular inspection/maintenance for the door and operator should be performed at regular intervals to ensure the system runs at peak safety, performance and efficiency. MAINTENANCE ITEM INTERVALS DETAILS Contact Reverse Test Monthly See Page 27 to run system test. Lubricate Door Hardware Monthly Lubricate Rollers &...
  • Page 40: Replacing Batteries

    2. Open operator lens cover by pressing in on upper locking tab and lower cover. 3. Replace old light bulbs with 15 Watt MAXIMUM LED equivalent**. * Genie LED light bulbs, which are specifically made for garage door operators, are recommended.
  • Page 41: Troubleshooting & Led Signals

    TROUBLESHOOTING & LED SIGNALS Use the guide below along with the self diagnostic operator LEDs to help troubleshoot any problems. Need help or have questions? DO NOT RETURN to the store. Visit www.genicompany.com or call Customer Service at 1-800-35-GENIE. PROBLEM: WHAT TO DO: Operator does NOT •...
  • Page 42 LED SIGNALS OPERATOR LEDS Operator LED Solution Possible Problem Long LED Round LED Normal operation. None required. Check power supply. No response from unit. Contact a trained door system professional. ON/RED/ ON/RED/ Limits NOT set properly. Re-program limits, see pages 25-26. STEADY STEADY Program error.
  • Page 43: Replacement Parts

    REPLACEMENT PARTS Specify model number of operator when ordering parts Some hardware listed here shows size and/or type so they may be sourced locally if lost. Complete hardware bags can be ordered separately. For Heavy Duty 12’ & 14’ Rails Only Chain &...
  • Page 44 DC Chain/Belt Drive Operator Specify model number of operator when ordering parts GENIE Manual Item Part Number Descrip�on 38240B.S Power Cord Assembly See #6 Light Socket Assembly 39360R.S Op�cal Dual Encoder 41014R.S Motor Assembly w/Encoder 36947A.S Screw, 6-18 x 3/8, Self Tap 38874R3.S...
  • Page 45: Dasma Safety Guidelines

    DASMA SAFETY GUIDELINES Look for this Safety Alert Symbol below. This symbol indicates a potential personal safety hazard that can result in injury or death. A GARAGE DOOR IS THE LARGEST MOVING OBJECT IN THE HOME. These doors are often operated by electric door operators. Proper installation, operation, main- tenance, and testing of the garage door and automatic operator are necessary to provide safe, trouble-free operation.
  • Page 46 WHEN USING THE PUSH BUTTON OR The push button wall control should TRANSMITTER, KEEP THE DOOR IN SIGHT be out of reach of children. UNTIL IT COMPLETELY STOPS MOVING. (at least 5 feet from the floor) and Teach children never to play under or near an open away from all moving parts.
  • Page 47: Warranty

    Commercial Operator Limited Warranty The Genie Company (“Seller”) warrants to the original purchaser of this commercial door operator ”Product”), subject to all of the terms and conditions hereof, that the Product and all components thereof will be free from defects in materials and workmanship under normal use for the following period(s), measured from the date of installation.
  • Page 48 The Genie Company One Door Drive Mount Hope OH. 44660 1-800-843-4084 www.geniecompany.com...

This manual is also suitable for:

Opgldt0011Opgldt0011wOpgldt0011wb

Table of Contents