Special Installation Information; Changing Force Settings - Genie GCL-LT Manual

Light-duty trolley operator for sectional doors
Table of Contents

Advertisement

SPECIAL INSTALLATION INFORMATION

5

Changing Force Settings

WARNING
!
TO AVOID INJURY OR DAMAGE
NEVER adjust the force settings to adjust for damage,
including an unbalanced door, binding door track or
broken spring.
Perform a CONTACT REVERSE TEST monthly.
Force Settings:
Force settings are pre-programmed at the factory and applied during the Open/Closed Limit settings steps.
For normal use, these settings should not need adjustment. Open and close limits must be set and
door run one full cycle to store force profile before force control adjustments can be changed.
Conditions possibly requiring adjustments are:
1. Doors with very stiff weather seals.
2. Doors that start down, STOP, and reverse before closing.
3. Doors that start up, but STOP before they completely open.
1. Press and hold both UP & DOWN arrow buttons until
the ROUND LED turns RED. Release buttons.
• LEDs will show current force level. SEE CHART.
2. Press either the UP or DOWN arrow button until the
desired UP force setting is shown. SEE CHART.
3. Press & release the PRGM button to lock the desired UP
FORCE setting.
• LEDs will now show the current DOWN FORCE setting.
SEE CHART.
4. Press either the UP or DOWN arrow button until
desired DOWN force setting is shown. SEE CHART.
5. Press & release the PRGM button to lock the desired
DOWN FORCE setting.
• Both LEDs will turn BLUE then go out confirming that
the force settings have been changed and are locked.
6. Operator is now ready to operate and test.
7. Operate door from the wall console two full cycles
then perform safety contact reverse test. (SEE PAGE 8)
Force Level
1 (LOWEST)
2
3
4
5
6
7
8
9 (HIGHEST)
FORCE SETTING CHART
Long LED
OFF
BLUE
BLUE
OFF
VIOLET
VIOLET
OFF
RED
RED
AVERTISSEMENT
!
Pour éviter les blessures ou des dommages
NE JAMAIS régler la force pour compenser des
dommages, y compris une porte mal équilibrée, un rail
de porte coinçant ou des ressorts cassés.
Tous les mois, EFFECTUEZ LE TEST D'INVERSION AU
CONTACT.
Round LED
BLUE
OFF
BLUE
VIOLET
OFF
VIOLET
RED
OFF
RED
PRESS & RELEASE
PRGM
SET
Flashing
RED
PRGM
SET
See Chart for
Force level
indicators.
PRGM
SET
Press PRGM to
lock settings
33