PROGRAMMING OPERATOR AND ACCESSORIES

4
NOTE: Before programming the operator, check to make sure there are no objects in the garage door opening.
DO NOT allow persons to enter the area of the door while programming and operating.
The following steps list the order of programming the operator's functional settings and install any accessories
that were included with the operator or purchased separately. These steps should be performed in order.
1. Down Travel Limit
2. Up Travel Limit
3. Force Control
4. Contact Reverse test and adjustment
5. Accessory Programming
• Program wireless keypad (If applicable)
• Program built in vehicle remote (If applicable)
• Program wireless wall console (If applicable)
• Program the Integrated Aladdin Connect (if applicable)
6. Connect Battery Backup to operator (if applicable)
Term Definitions:
Travel Limits - Programmable setting to adjust how far door travels up or down.
Force Control - refers to how much power is needed to move (open/close) a particular door and
does NOT require programming.
Remote & Accessory Programming - synchronizes remote devices with the operator.
(Remote Controls, Wireless Keypad, Homelink®, Car-2-U® Systems)
Speed Control - refers to how fast or slow the operator opens and closes the door. This is factory set
and does NOT require programming. NOT available on all models.
Round LED
Indicator
Long LED
Indicator
NOTE: Each programming step has a 30 second time limit for completion after the function is initiated. After
30 seconds, both LEDs will illuminate RED indicating time has expired and the step must be restarted. Restart
the step as many times as necessary to complete the programming.
24
Programming Button Layout
Program/Set
PRGM
SET
DOOR
Open Travel
Button
Close Travel
Button