INSTALL AND WIRE MONITORED SAFETY DEVICE

Wireless Monitored Safety Edge (Optional)

Actuating the operator by using constant contact on the CLOSE button will override non-functioning
external reversing devices, including sensing edges.
L'activation de l'operateur en util isant un contact constant sur le bouton FERMER annulera les dispositifs
d'inversions externes, y compris les systèmes de détection des bords.
MillerEdge® Wireless Monitored Sensing Edge Installation
CAUTION: THIS PROCEDURE MUST BE PERFORMED WITH THE DOOR IN THE CLOSED POSITION ONLY.
Door Installation - Wireless Edge System:
1. Move door to the fully closed position.
2. Remove power from the unit. Use proper lock-out/tag-out procedures. (Refer to OSHA Standard
1910.147).
3. Mount the RBand receiver near the operator operator in a dry area.
4. Route wire from RBand receiver to operator operator and attach as shown below.
5. Mount RBand RB-TX10 transmitter, GT3C converter (when required), transformer (when required) and
edge sensor as shown in the manufacturers instructions.
6. Wire safety edge, GT3C converter (when required) per application using table above.
7. Insert batteries into the RB-TX10 transmitter and GT3C converter (when required)
8. Apply power to operator.
9. Follow RBand instruction sheet to learn the RB-P-K10 receiver to the RB-TX10 transmitter.
10. Program operator ODC-STB to the ON status (see installation manual).
11. Run full operational and safety function test.
MONITORED Door Installation
T2/T3 Safety Edge
RBand RB-TX10
Transmitter
20
WARNING
!
AVERTISSEMENT
!
RB-P-K10
Operator
Receiver
24V AC
Transformer
Used Only With T3 Edge
RBand GT3C
Converter
T3 Red
Band /
T2 Blue
Band
RBand RB-TX10
RB-P-K10 Receiver
White
White
Yellow
Blue
RBand Transmitter & Converter Wiring Installation for Wireless T2/T3 Safety Edge
Transmitter
Light-Duty Commercial Operator (Trolley)
Control Wire
Terminals
RBand GT3C
Converter
(Only Used With T3 Edge)
115 VAC
to 24 VAC
Transformer
P/N: 36238A
(Not Included)
T3 ONLY
T2/T3
Safety
Edge
T3 Edge
T2 Edge
Red Band
Blue Band