Combination Of Ad75 Main Functions And Auxiliary Functions - Mitsubishi Electric A1SD75P1-S3 User Manual

Positioning module
Table of Contents

Advertisement

3 SPECIFICATIONS AND FUNCTIONS

3.3.4 Combination of AD75 main functions and auxiliary functions

With positioning control using the AD75, the main functions and auxiliary functions can
be combined and used as necessary. A list of the main function and auxiliary function
combinations is given below.
Main functions
Machine zero point return control
Zero point return
control
High-speed zero point return control
Position control
Main positioning
control
Speed control
Speed/position changeover control
Other control
JOG operation
Manual control
Manual pulse generator operation
: Always combine,
: Combination possible,
1
*
The operation pattern is one of the "positioning data" setting items.
2
*
Disabled for a start of positioning start No. 9003.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Combination with
operation pattern.*
1-axis linear control
2-axis linear
interpolation control
1-axis fixed-dimension
feed control
2-axis fixed-dimension
feed control
(interpolation)
2-axis circular
interpolation control
Current value change
JUMP command
: Combination limited,
3 - 10
Auxiliary functions
1
(Continuous path control
cannot be set)
(Continuous path control
cannot be set)
(Only independent positioning
control can be set)
(Continuous path control
cannot be set)
(Continuous path control
cannot be set)
(Independent positioning
control cannot be set)
: Combination not possible, –: Setting invalid
MELSEC-A
Functions characteristic
to machine zero point
return

Advertisement

Table of Contents
loading

This manual is also suitable for:

A1sd75p2-s3A1sd75p3-s3Ad75p1-s3Ad75p2-s3Ad75p3-s3

Table of Contents