Manual Pulse Generator Operation; Outline Of Manual Pulse Generator Operation - Mitsubishi Electric A1SD75P1-S3 User Manual

Positioning module
Table of Contents

Advertisement

11 MANUAL CONTROL

11.3 Manual pulse generator operation

11.3.1 Outline of manual pulse generator operation

Cd 22 Manual pulse
generator enable flag
BUSY signal [X4, X5, Y6]
Manual pulse
generator input
Positioning start complete
signal
[Precautions]
1
*
When the input from the manual pulse generator stops, the last pulse will be output from the
AD75, delayed by the time for one control cycle (100ms).
2
*
The start complete signal does not turn ON in manual pulse generator operation.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Important
Create the sequence program so that " Cd.22 Manual pulse generator enable flag"
is always set to "0" (disabled) when a manual pulse generator operation is not
carried out.
* Mistakenly touching the manual pulse generator when the manual pulse
generator enable flag is set to "1" (enable) can cause accidents or incorrect
positioning.

Manual pulse generator operation

In manual pulse generator operations, pulses are input to the AD75 from the
manual pulse generator. This causes the same No. of input pulses to be output
from the AD75 to the servo amplifier, and the workpiece is moved in the
designated direction.
The following shows and example of manual pulse generator operation.
When the " Cd.22 Manual pulse generator enable flag" is set to "1", the BUSY signal
1)
turns ON and the manual pulse generator operation is enabled.
The workpiece is moved corresponding to the No. of pulses input from the manual pulse
2)
generator.
The workpiece movement stops when no more pulses are input from the manual pulse
3)
generator.
When the " Cd.22 Manual pulse generator enable flag" is set to "0", the BUSY signal
4)
turns OFF and the manual pulse generator operation is disabled.
1) 2)
ON
0
1
ON
OFF
OFF
2
*
[X1, X2, X3]
Manual pulse generator operation enabled
Fig. 11.11 Manual pulse generator operation
11 - 17
MELSEC-A
Manual pulse
generator
1
operation stops
*
t
3)
4)
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

A1sd75p2-s3A1sd75p3-s3Ad75p1-s3Ad75p2-s3Ad75p3-s3

Table of Contents