Mitsubishi Electric A1SJ71AP23Q User Manual
Mitsubishi Electric A1SJ71AP23Q User Manual

Mitsubishi Electric A1SJ71AP23Q User Manual

Melsecnet, melsecnet/b local station data link module

Advertisement

MELSECNET, MELSECNET/B
Local Station Data Link Module
A1SJ71AP23Q, A1SJ71AR23Q
Thank you for purchasing the Mitsubishi programmable controller
MELSEC-A series.
Prior to use, please read this and relevant manuals thoroughly to
fully understand the product.
© 2007 MITSUBISHI ELECTRIC CORPORATION
User's Manual
A1SJ71AT23BQ
MODEL A1SJ71AP23Q-U-HW
MODEL
CODE
IB(NA)-0800372-E(1806)MEE
(Hardware)
13JY19

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric A1SJ71AP23Q

  • Page 1 (Hardware) A1SJ71AP23Q, A1SJ71AR23Q A1SJ71AT23BQ Thank you for purchasing the Mitsubishi programmable controller MELSEC-A series. Prior to use, please read this and relevant manuals thoroughly to fully understand the product. MODEL A1SJ71AP23Q-U-HW MODEL 13JY19 CODE IB(NA)-0800372-E(1806)MEE © 2007 MITSUBISHI ELECTRIC CORPORATION...
  • Page 2: Safety Precautions

    SAFETY PRECAUTIONS (Read these precautions before using this product.) Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product only. For the safety precautions of the programmable controller system, please read the User's Manual for the CPU module used.
  • Page 3 [DESIGN PRECAUTIONS] WARNING ● To control a running programmable controller (data modification) by connecting GX Developer to a CPU module or connecting a personal computer to an intelligent function module (special function module), create an interlock circuit on the sequence program so that the entire system will function safely all the time.
  • Page 4 [INSTALLATION PRECAUTIONS] CAUTION ● Use the programmable controller in the environment conditions given in the general specifications of the User's Manual for the CPU module used. Failure to do so may cause an electric shock, fire, malfunction, or damage to or deterioration of the product.
  • Page 5: Wiring Precautions

    [WIRING PRECAUTIONS] WARNING ● Be sure to shut off all phases of the external power supply before installation or wiring. Failure to do so may result in an electric shock or damage to the product. CAUTION ● Properly solder a connector for coaxial cable. Failure to do so may cause malfunction.
  • Page 6 [START-UP AND MAINTENANCE PRECAUTIONS] CAUTION ● Do not disassemble or remodel each of the modules. Doing so may cause failure, malfunctions, personal injuries and/or a fire. ● When using a wireless communication device such as a mobile phone, keep a distance of 25cm (9.84inch) or more from the programmable controller in all directions.
  • Page 7 PRÉCAUTIONS DE SÉCURITÉ (Lire ces précautions avant toute utilisation du produit.) Avant d'utiliser ce produit, lire attentivement ce manuel ainsi que les manuels auxquels il renvoie, et toujours considérer la sécurité comme de la plus haute importance en manipulant le produit correctement. Les précautions à...
  • Page 8 [PRÉCAUTIONS DE CONCEPTION] AVERTISSEMENT ● Pour intervenir sur un automate programmable pendant la marche (pour une modification de données) en raccordant l'outil GX Developer à un module CPU ou en raccordant un ordinateur individuel à un module fonctionnel intelligent (module des fonctions spéciales), configurer dans le programme séquentiel un circuit de verrouillage permettant de garantir en tous temps la sécurité...
  • Page 9 [PRÉCAUTIONS D'INSTALLATION] ATTENTION ● Utiliser l'automate programmable dans dans les conditions environnementales prescrites en section Spécifications générales du Manuel de l'utilisateur du module CPU utilisé. Faute de quoi, il y aurait risque de choc électrique, de départ de feu, de dysfonctionnement, d'endommagement ou de détérioration du produit.
  • Page 10 [PRÉCAUTIONS DE CABLAGE] AVERTISSEMENT ● Toujours couper l'alimentation externe sur toutes les phases avant l'installation et le câblage. Faute de quoi, il y aurait risque de chocs électriques ou d'endommagement du produit. ATTENTION ● Souder correctement un connecteur pour câble coaxial. Le non-respect de cette précaution expose à...
  • Page 11 [PRÉCAUTIONS DE MISE EN SERVICE ET DE MAINTENANCE] ATTENTION ● Ne pas tenter de démonter ou de modifier les modules. Cela pourrait être à l'origine de pannes, dysfonctionnements, blessures et/ou d'un départ de feu. ● Pour utiliser un appareil de communication sans fil, comme un téléphone portable, le tenir éloigné...
  • Page 12 CONDITIONS OF USE FOR THE PRODUCT (1) Mitsubishi programmable controller ("the PRODUCT") shall be used in conditions; i) where any problem, fault or failure occurring in the PRODUCT, if any, shall not lead to any major or serious accident; and ii) where the backup and fail-safe function are systematically or automatically provided outside of the PRODUCT for the case of any problem, fault or failure occurring in the PRODUCT.
  • Page 13 Notwithstanding the above, restrictions Mitsubishi may in its sole discretion, authorize use of the PRODUCT in one or more of the Prohibited Applications, provided that the usage of the PRODUCT is limited only for the specific applications agreed to by Mitsubishi and provided further that no special quality assurance or fail-safe, redundant or other safety features which exceed the general specifications of the PRODUCTs are required.
  • Page 14 Chinese standardized law. This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
  • Page 15: Table Of Contents

    Handling Precautions ................9 4. PART NAMES AND SETTINGS..............10 5. WIRING ......................13 Optical Fiber Cable ................13 Coaxial Cable..................14 Shielded Twisted Pair Cable ............... 17 6. EXTERNAL DIMENSIONS................18 A1SJ71AP23Q ..................18 A1SJ71AR23Q..................19 A1SJ71AT23BQ.................. 20 A-14...
  • Page 16 ABOUT MANUALS The following manuals are also related to this product. Order them by referring to the table below as necessary. Related Manuals Manual number Manual name (Model code) MELSECNET, MELSECNET/B Local Station Data Link SH-080670ENG Module User's Manual (13JR98) Type MELSECNET, MELSECNET/B Data Link System IB-66350 Reference Manual...
  • Page 17 COMPLIANCE WITH THE EMC AND LOW VOLTAGE DIRECTIVES (1) Method of ensuring compliance To ensure that Mitsubishi programmable controllers maintain EMC and Low Voltage Directives when incorporated into other machinery or equipment, certain measures may be necessary. Please refer to one of the following manuals. •...
  • Page 18: Overview

    This manual describes the specifications and part names of the data link module shown below used in the MELSECNET or MELSECNET/B data link system (hereinafter referred to as a local module). • A1SJ71AP23Q type MELSECNET local station data link module • A1SJ71AR23Q type MELSECNET local station data link module •...
  • Page 19 (3) The following shows the applicable modules and maximum number of mounted modules for the local module. (a) For the Q series • Applicable modules High Performance model QCPU Universal model QCPU whose serial number (first five digits) is "13102" or later QA1S5 B, QA1S6 B, and QA6 B+A-A1S module conversion adapter •...
  • Page 20: Performance Specifications

    For the general specifications, refer to the User's Manual (Hardware Design, Maintenance and Inspection) for the CPU module used. (1) Performance specifications of MELSECNET data link system and A1SJ71AP23Q Table 2.1 Performance specifications of MELSECNET data link system and A1SJ71AP23 Specifications...
  • Page 21 Also, a connector dedicated to an optical fiber cable is required. For purchase, contact your local Mitsubishi Electric System Service or representative. *1 Le raccordement d'un câble à fibres optiques à un connecteur ne peut être effectué que par un professionnel disposant de l'outillage spécial.
  • Page 22 (2) Performance specifications of MELSECNET data link system and A1SJ71AR23Q Table 2.2 Performance specifications of MELSECNET data link system and A1SJ71AR23Q Specifications MELSECNET data link system Item MELSECNET MELSECNET II MELSECNET II mode mode composite mode Maximum Up to the maximum number of I/O points for the CPU module Input (X) applicable link used in the master station is applicable.
  • Page 23 Table 2.2 Performance specifications of MELSECNET data link system and A1SJ71AR23Q (Continued) Specifications MELSECNET data link system Item MELSECNET MELSECNET II MELSECNET II mode mode composite mode Connector plug for 3C-2V (User prepared): • BNC-P-3-NiCAu-CF (DDK Ltd.) Connector plug for 5C-2V (User prepared): •...
  • Page 24 (3) Performance specifications of MELSECNET/B data link system and A1SJ71AT23BQ Table 2.3 Performance specifications of MELSECNET/B data link system and A1SJ71AT23BQ Specifications MELSECNET/B data link system Item MELSECNET MELSECNET II MELSECNET II mode mode composite mode Maximum Up to the maximum number of I/O points for the CPU module Input (X) applicable link used in the master station is applicable.
  • Page 25 Remarks Overall cable distance (1) MELSECNET data link system The overall cable distance refers to a distance from OUT of the master station to IN of the master station via a slave station. Overall cable distance of MELSECNET MELSECNET Figure 2.1 Overall cable distance of MELSECNET (2) MELSECNET/B data link system The overall cable distance refers to a distance between stations at both ends.
  • Page 26: Handling

    3. HANDLING 3.1 Handling Precautions (1) Do not drop or give strong impact on the module, since its case is made of resin. (2) Do not remove a printed-circuit board of the module from a case. Doing so may cause failure. (3) Be careful to prevent foreign matter such as wire chips from entering the module top at the time of wiring.
  • Page 27: Part Names And Settings

    4. PART NAMES AND SETTINGS This chapter describes the part names and settings of the local module. Figure 4.1 Outside drawing of local module Table 4.1 Part names and settings Name Description Name Status Description Data link normal Data sending Data receiving Forward loop side receives data (OFF: F.LOOP...
  • Page 28 Receive error at reverse loop side Station No. setting switch Sets station No. of the local module. (Factory default setting: 1) (A1SJ71AP23Q/ • A1SJ71AP23Q/A1SJ71AR23Q A1SJ71AR23Q) 1 to 64: Station No. Tens place (If other than above is set, the local module goes into offline status (X0=ON).)
  • Page 29 Unusable (If set, the local module goes into offline 4 to F status (X0=ON).) Connects an optical fiber cable. Raccordement par câble à fibres optiques Connector (A1SJ71AP23Q) Reverse loop send Connecteur Foward loop receive (A1SJ71AP23Q) Foward loop send Reverse loop receive Connects a coaxial cable.
  • Page 30: Wiring

    5. WIRING 5.1 Optical Fiber Cable This section describes how to connect an optical fiber cable with the local module. (1) Precautions for wiring (a) Securing of wiring space When an optical fiber cable is connected with the local module, a cable bend radius is restricted.
  • Page 31: Coaxial Cable

    5.2 Coaxial Cable This section describes how to connect a coaxial cable with the local module. (1) Precautions for wiring (a) Securing of wiring space When a coaxial cable is connected with the local module, a cable bend radius is restricted. Local module Figure 5.2 Allowable bend radius of coaxial cable...
  • Page 32 (3) Connection of cable for coaxial cable The following shows how to connect a BNC connector (connector plug for coaxial cable) and a cable. (a) Components of BNC connector and coaxial cable Components of BNC connector Components of coaxial cable External conductor External sheath Insulator...
  • Page 33 Insulator Internal conductor Clamp and external conductor Applicable cable 3C-2V 6mm (0.24 in. ) 3mm (0.12 in.) 5C-2V 7mm (0.28 in.) 5mm (0.2 in.) 4) Solder a contact to the internal conductor. Solderd 5) Insert a contact assembly in 4) to a plug shell and screw a nut into the plug shell.
  • Page 34: Shielded Twisted Pair Cable

    5.3 Shielded Twisted Pair Cable This section describes how to connect a shielded twisted pair cable with the local module. (1) Precautions for wiring (a) Laying shielded twisted pair cable When laying a shielded twisted pair cable, pay attention to the following points so that it will not be affected by noise or surge induction.
  • Page 35: External Dimensions

    6. EXTERNAL DIMENSIONS 6.1 A1SJ71AP23Q Printed-circuit board 93.6 34.5 Unit: mm Figure 6.1 A1SJ71AP23Q For details, contact your local Mitsubishi Electric System Service or representative.
  • Page 36: A1Sj71Ar23Q

    6.2 A1SJ71AR23Q Printed-circuit board 93.6 34.5 Unit: mm Figure 6.2 A1SJ71AR23Q...
  • Page 37: A1Sj71At23Bq

    6.3 A1SJ71AT23BQ Printed-circuit board 71.6 34.5 93.6 Unit: mm Figure 6.3 A1SJ71AT23BQ...
  • Page 38 Memo...
  • Page 40 20 Waterford Office Park, 189 Witkoppen Road, Avenida Adelino Cardana, 293, 21 andar, Fourways, South Africa Bethaville, Barueri SP, Brazil Tel : +27-11-658-8100 Tel : +55-11-4689-3000 Germany MITSUBISHI ELECTRIC EUROPE B.V. German China MITSUBISHI ELECTRIC AUTOMATION (CHINA) Branch LTD. Mitsubishi-Electric-Platz 1, 40882 Ratingen, No.1386 Hongqiao Road, Mitsubishi Electric...

This manual is also suitable for:

A1sj71ar23qA1sj71at23bq