Maintenance
10.5 Corrective maintenance
• Do not reuse bearings that have been removed.
• Remove the dirty spent grease from the bearing shield.
• Replace the existing grease with new grease.
• Replace the shaft seals when the bearings are replaced.
• Slightly grease the contact surfaces of the sealing lips.
Note
Special operating conditions
The operating hours are reduced, e.g.
• When machines are vertically mounted.
• High vibration and surge loads
• Frequent reversing operation
• Higher ambient temperatures.
• High speeds etc.
Heat up 80 ... 100 °C
10.5.2.1

Bearing bushes

Protect the bearings against the ingress of dirt and moisture.