10.5 Corrective maintenance
For operational braking, the maintenance intervals depend on the loading on the brake in
the application. Take all causes of wear into account when calculating the maintenance
intervals. Siemens recommends a regular inspection at fixed time intervals for brakes that are
subject to low loads, e.g. holding brakes with an emergency stop.
Failure to maintain the brake can lead to operating faults, production outage or damage
to the plant. Specify a maintenance plan for each application that is appropriate to the
operating conditions and loading of the brake. The maintenance intervals and maintenance
work for the pneumatic brake are listed in the table.
Table 10-6
Brake
Operational brake
Holding brake with emergency
stop
Adjusting the air gap
Unintentional starting of the drive unit
Switch off the power supply to the drive unit.
The brake must be in a torque-free condition.
Secure the drive unit to prevent it from being started up unintentionally.
Attach a warning notice to the start switch.
Decrease of braking effect due to contamination
Do not allow oil or grease to come into contact with friction surfaces.
120
Maintenance interval for the brake
WARNING
WARNING
Maintenance interval
According to service life calculation
Otherwise every six months
After 4 000 operating hours at the latest
Minimum every 2 years
After 1 million cycles at the latest
Shorter intervals for frequent emergency stops