Troubleshooting
Troubleshooting Guide
Error Code
Error
E107
Operating system:
NVRAM-FLASH
structure data error.
E108
Operating system:
NVRAM-FLASH
checksum data error.
E109
Operating system:
NVRAM fatal read
error.
E110
Operating system:
CORE maximum
SYNCH_DURATION.
E111/F5
Operating system:
Error in control board
checksum.
E112/F5
Operating system:
Error in relay board
checksum.
E113
Operating system:
Kernel stack overflow
in the control board.
E114
Operating system:
Kernel stack error in
the relay board.
E115/F29
Door lock not
initialized.
E116
Door lock switch.
E117/F29
Short in the motor
circuit for the door
lock.
E118/F29
Open circuit in the
motor for the door
lock.
E119/F5
External firmware error.
E120/F5
SOUNDLIBRARY error.
E121/F5
PICTURELIBRARY
error.
E122/F5
TEXTLIBRARY error.
E123/F5
FONTLIBRARY error.
E124/F5
MODELCONFIGLIBRA
RY error.
E125/F5
PRESENTATIONLIBRA
RY error.
E131/F5
FACTORYSETTINGLIB
RARY error.
E132/F5
EASYCOOK data
invalid.
E133/F32
Calibration value error
in the water level
measurement.
E136/F16
Thermostat 160C
defective.
E137/F16
Actuator defective.
827703 REV B.1
Possible Cause
Test/Action
2
Moisture on control
1
board.
2
Moisture on control
1
board.
2
Moisture on control
1
board.
2
Moisture on control
1
board.
2
Replace the control board.
Replace the control board and relay board.
Replace the control board.
Replace the relay board.
1
2
1
2
1
2
1
2
Replace the control board.
Replace the control board.
Replace the control board.
Replace the control board.
Replace the control board.
Replace the control board.
Replace the control board.
Replace the control board.
Replace the control board.
Replace the control board.
Replace the thermostat 160C.
High resistance to
1
element, bake element,
91
CSO (SWS #13543126)
Replace the control board if the error continues.
Inspect the control board for moisture.
Replace the control board if the error continues.
Inspect the control board for moisture.
Replace the control board if the error continues.
Inspect the control board for moisture.
Replace the control board if the error continues.
Inspect the control board for moisture.
Replace the control board if the error continues.
Check the wiring.
Replace the relay board.
Check the wiring.
Replace the relay board.
Check the wiring.
Replace the relay board.
Check the wiring.
Replace the relay board.
Check all the element wiring.