Change The Set Point; Initiate Manual Defrost - True GDM-HST02-HC-TSL01 Installation Manual

Table of Contents

Advertisement

Electronic Temperature Control (cont.)

Change the Set Point

Changing the set point adjusts the appliance temperature to
keep optimal product temperature.
NOTICE ›
The set point value is NOT the appliance
holding temperature. To maintain proper operation within a
safe temperature range and prevent an alarm activation, it is
recommended to only change the value by a few degrees.
1. Press and hold info
DO NOT RELEASE THE BUTTON!
current set point.
2. While holding info, press the up
arrows to adjust the setting.
3. Release all buttons and wait for the control to display the
current appliance temperature.
Page 32 of 48
L A E C O N T R O L L E G E N D
until the display shows the
or down
GDM-HST02
Compressor Running
Evaporator Fan Running
Appliance in Defrost
Activation of 2
Alarm

Initiate Manual Defrost

A manual defrost clears accumulated frost and ice from the
evaporator coil. The defrost will only terminate when a specific
preset temperature or duration has been met.
Press Manual Defrost
12/4/2023
Info/Set Point
nd
Parameter Set
Manual Defrost/
Down Arrow
until the display shows deF.
P#840669
truemfg.com
Manual Activation/
Up Arrow
Stand-By/
Cancel
TEC_TM_158 | REV. B | EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gdm-23-hst02-hc-tsl01Gdm-26-hst02-hc-tsl01