Electronic Temperature Control; Display Codes - True GDM-HST02-HC-TSL01 Installation Manual

Table of Contents

Advertisement

Electronic Temperature Control

Electronic Temperature Control
Display
Definition
hSt
Health Safety Timer password entry
dLc
Door Lock / Unlock password entry
Loc
Keypad state lock
t1
Instant probe 1 temperature
t2
Instant probe 2 temperature
t3
Instant probe 3 temperature
min
Minute of the real time clock
hrS
Hours of the real time clock
Stt
Start time for timed actions
Edt
End time for timed actions
thi
Maximum probe 3 temperature recorded
tLo
Minimum probe 3 temperature recorded
TEC_TM_158 | REV. B | EN
GDM-HST02
L A E C O N T R O L L E G E N D
D I S P L A Y C O D E S
Display
dEF
oFF
do
hi
Lo
E1
E2
E3
hSt/dLY
hSt/tSt
hLA/Loc
PF
12/4/2023
Compressor Running
Evaporator Fan Running
Appliance in Defrost
Activation of 2
nd
Parameter Set
Alarm
Definition
Defrost in progress
Controller in stand-by
Door open alarm
Appliance high temperature alarm
Appliance low temperature alarm
Probe t1 failure
Probe t2 failure
Probe t3 failure
Delays checking of Health Safety Timer
conditions
Testing the Health Safety Lock
Health Safety Alarm / lockout active
Power failure
truemfg.com
Info/Set Point
Manual Activation/
Up Arrow
Manual Defrost/
Stand-By/
Down Arrow
Cancel
Page 27 of 48

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gdm-23-hst02-hc-tsl01Gdm-26-hst02-hc-tsl01

Table of Contents