Electronic Temperature Control (cont.)
Clear the Health Safety Alarm or Product
Loading & Servicing Delay
NOTICE ›
Clearing the Health Safety Alarm through the
display will return the appliance to its state prior to the
alarm activation (locked or unlocked).
1. Press info
to show hSt.
2. Press and hold info until the display shows 00.
DO NOT RELEASE THE BUTTON!
3. While holding info, press the up arrow until the display
shows 01.
4. Release all buttons and wait for the control to display the
current appliance temperature.
TEC_TM_158 | REV. B | EN
GDM-HST02
L A E C O N T R O L L E G E N D

Silence the Door Open Alarm

If the door remains open for 5 minutes, the control emits a
series of beeps and the display flashes do.
To silence the alarm, shut the door or press ANY button on
the control. The display will continue to flash do until the door
closes.
12/4/2023
Compressor Running
Evaporator Fan Running
Appliance in Defrost
Activation of 2
nd
Parameter Set
Alarm
truemfg.com
Info/Set Point
Manual Activation/
Up Arrow
Manual Defrost/
Stand-By/
Down Arrow
Cancel