Installation Compliance - Drolet ECO-55 Installation Manual

Hide thumbs Also See for ECO-55:
Table of Contents

Advertisement

+HUH LV DQ H[DPSOH WR KHOS \RX FDOFXODWH (TXLYDOHQW
9HQW /HQJWK 2Q WKH IROORZLQJ ¿JXUH WKH (9/ FDQ EH
calculated like this:
2 feet of horizontal run (2 X 1' EVL) = 2' of EVL
90° elbow or "Tee" (1 X 5' EVL)
12 feet of vertical run
(12' X 0.5' EVL)
Termination cap
Total EVL
Since the total EVL is less than 15 feet, the re-
commended exhaust venting diameter is 3".

4.3.2 INSTALLATION COMPLIANCE

To determine if your installation is compliant, the
H[KDXVW YHQWLQJ V\VWHP PXVW HQG ZLWKLQ WKH JULG RQ
the venting system chart. The previous installation
has 2 feet of horizontal run and 12 feet of vertical
run. It is thus standard since the venting system ends
in the gridded area.
CAUTION
+RUL]RQWDO UXQV VKDOO QRW H[FHHG  IHHW
1HYHU H[FHHG  IHHW RI HYO
Page 10
=5' of EVL
TO REDUCE THE RISK OF SMOKE SPILLAGE
= 6' of EVL
THERE SHOULD ALWAYS BE AT LEAST ONE
FOOT OF VERTICAL RISE FOR EACH FOOT OF
= 0' of EVL
HORIZONTAL RUN. IN ALL CASES, AT LEAST 3
FEET OF VERTICAL RISE IS NEEDED.
= 13' of EVL
TERMINATION OF A SIDE WALL VENT SHOULD
BE LOCATED TO AVOID PERSONAL BURN
INJURY, FIRE HAZARD AND INTERFERENCE
WITH
PROPERTIES. EXHAUST GASES CAN REACH
TEMPERATURES OF 500°F (260°C) AND CAUSE
SERIOUS BURNS.
TERMINATION COLLAR (SPARK ARRESTER)
IS MANDATORY AND MUST BE CLEAR OF ANY
DEBRIS AT ALL TIME.
INSTALLATION MANUAL ECO-55 / ECO-55 CT / ECO-55 ST