Compliance Of A Combustible Mantel Shelf - Drolet Escape 1400 Insert Installation And Operation Manual

Table of Contents

Advertisement

Escape 1400 Insert Installation and Operation Manual

7.3 Compliance of a Combustible Mantel Shelf

To ensure compliance of an existing mantel shelf or to install a combustible mantel shelf,
refer to table and figure below. For example, a mantel shelf with a 6'' depth (152 mm) ((X)
value) must be installed at least 29" (737 mm) ((I) value) above the top of the insert (see
figure below). Different mantel shelf dimensions are listed in the following table. However,
no combustible mantel shelf can be installed at less than 29" (737 mm) above the top of
the insert. If the depth of the mantel shelf is not listed in the table below, add 23" (584
mm) to the depth of your mantel shelf to obtain the safe positioning of your mantel shelf.
For example, for a 9" (229 mm) mantel shelf, the safe positioning would be 32" (813 mm)
above the top of the insert (23" (584 mm) + 9" (229 mm)).
MAXIMUM MANTEL
SHELF DIMENSION
(X)
6" / 152 mm
8" / 203 mm
10" / 254 mm
12" / 305mm
MANTEL SHELF
CLEARANCES
(I)
29" (737 mm)
31" (787 mm)
33" (838 mm)
35" (889 mm)
31