3. CLEARANCES TO COMBUSTIBLE
MATERIALS
The clearances shown in this section applies to
DP00070, DP00072 and DP00071.
The clearances shown in this section have been
determined by tests according to procedures set out in
safety standards ULC S627 (Canada), ASTM E1509
(U.S.A) and UL1482 (U.S.A.). When the pellet stove
is installed so that its surfaces are at, or beyond, the
PLQLPXP FOHDUDQFHV VSHFL¿HG FRPEXVWLEOH VXUIDFHV
will not overheat under normal and even abnormal
operating conditions.
NOTICE
The following clearances are also valid for an
alcove installation. However, if the stove is
installed in an alcove, to perform maintenance, you
VKRXOG H[SHFW WR PRYH WKH DSSOLDQFH WR JHW WR WKH
maintenance access doors and components.
3.1 CLEARANCES TO COMBUSTIBLES
MATERIALS, WALLS AND CEILING
MINIMUM CLEARANCES
CANADA
A*
3" (76 mm)
D
Note 1
I**
48" (1 220 mm)
*From the rear panel
0HDVXUHG IURP WKH SODWIRUP RQ ZKLFK WKH SURGXFW LV LQVWDOOHG
INSTALLATION MANUAL ECO-55 / ECO-55 CT / ECO-55 ST
USA
3" (76 mm)
Note 1
48" (1 220 mm)
Note 1 : Refer to the exhaust venting system manufacturer's
instructions for clearances to combustible materials.
RECOMMENDED CLEARANCES FOR
MAINTENANCE
CANADA
A*
12" (305 mm)
WARNING
NO PART OF THE PELLET VENT SYSTEM MAY
BE LOCATED CLOSER TO COMBUSTIBLES
THAN THE MINIMUM CLEARANCES SPECIFIED
BY THE VENT MANUFACTURER.
WARNING
NO PART OF THE STOVE MAY BE LOCATED
CLOSER TO COMBUSTIBLES THAN THE
MINIMUM CLEARANCES SPECIFIED ON THE
CERTIFICATION LABEL.
MINIMUM CLEARANCES
CANADA
B
6" (152 mm)
D
Note 1
RECOMMENDED CLEARANCES FOR
MAINTENANCE
CANADA
24" (610 mm)
B
USA
12" (305 mm)
USA
6" (152 mm)
Note 1
USA
24" (610 mm)