Through A Factory Built Chimney; Through An Existing Masonry Fireplace - Drolet ECO-55 Installation Manual

Hide thumbs Also See for ECO-55:
Table of Contents

Advertisement

4.6.3 7+528*+$)$&725<%8,/7&+,01(<
NOTICE
Before installation, the chimney must be cleaned
DQG LQVSHFWHG E\ D TXDOL¿HG FKLPQH\ VZHHS RU
installer.
1. Position stove following clearances given and fol-
lowing vent manufacturer's instructions.
2. Install a stove adapter or a stove adapter tee onto
WKH DSSOLDQFH ÀXH FROODU ,I QHFHVVDU\ XVH D KR-
UL]RQWDO DGGLWLRQDO OHQJWK EHWZHHQ WKH ÀXH RXWOHW
and the tee.
3. Use a proper chimney adaptor for your installa-
tion.
4. Run the number of sections of vent necessary to
go through the chimney adaptor into the chimney.
5. Connect the vent to a stainless steel 4" liner ac-
cording to the vent manufacturer's instruction.
6. ,QVWDOO URRI ÀDVKLQJ DQG UDLQ FDS DV SHU
manufacturer's instructions. If necessary, install
and seal a storm collar.
NOTICE
In the USA., the use of a stainless steel liner is
mandatory. In Canada, it is not mandatory but is
strongly recommended.
INSTALLATION MANUAL ECO-55 / ECO-55 CT / ECO-55 ST
4.6.4 THROUGH AN EXISTING MASONRY
),5(3/$&(
NOTICE
The structural condition of the masonry chimney
PXVW ¿UVW EH LQVSHFWHG E\ D TXDOL¿HG FKLPQH\
sweep or installer. You will need a pipe length
equal to the chimney height from the hearth. If
outside combustion air is to be used, you will need
a pipe length superior from 12 to 18 inches (30 to
46 cm) of the chimney height to ensure a proper
stove behaviour.
1. Position stove, following clearances and fol-
lowing vent manufacturer's instructions.
2. Build and Install a blocking plate inside the chim-
QH\ WR VHDO WKH ¿UHSODFH GDPSHU 6WDLQOHVV VWHHO
plate and screws are recommended. Cut a hole
IRU WKH H[KDXVW SLSH ,I QHHGHG FXW D VHFRQG KROH
for the air intake pipe
3. Attach a section of pipe and clean out tee to the
ÀXH RXWOHW PDNLQJ VXUH WKH FOHDQ RXW WHH LV FHQ-
WHUHG LQ WKH FKLPQH\ ÀXH DUHD
4. ,QVWDOO D YHQWHG ÀDVKLQJ DW WKH WRS RI WKH ¿UHSODFH
chimney. Stainless steel plate and screws are
recommended. Cut a hole for the vent pipe. If
needed, cut a second hole for the air intake pipe.
Seal all joints with high temperature waterproof
silicone sealant to prevent water leakage.
5. Seal and install vertical roof vent. If required, seal
and install a storm collar.
Page 13