Parameter list (by function group number)

 E: Environment setting
parameters
Parameters for the inverter operating environment.
Pr.
Pr.
group
Parameter for manufacturer setting. Do not
E000
168
set.
Parameter for manufacturer setting. Do not
E001
169
set.
Parameter for manufacturer setting. Do not
E023
269
set.
Parameter for manufacturer setting. Do not
E080
168
set.
Parameter for manufacturer setting. Do not
E081
169
set.
E100
75
Reset selection
E101
75
Disconnected PU detection
E102
75
PU stop selection
E103
145
PU display language selection
E104
990
PU buzzer control
E105
991
PU contrast adjustment
Frequency setting / key lock
E200
161
operation selection
RUN key rotation direction
E202
40
selection
Regenerative function
E300
30
selection
E400
77
Parameter write selection
E410
296
Password lock level
E411
297
Password lock/unlock
Parameter for manufacturer setting. Do not
E415
520
set.
E600
72
PWM frequency selection
E601
240
Soft-PWM operation selection
 F: Parameters for the settings of
the acceleration/deceleration time
and the acceleration/deceleration
pattern
Parameters
for
the
motor
characteristics.
Pr.
Pr.
group
Acceleration/deceleration
F000
20
reference frequency
Jog acceleration/deceleration
F002
16
time
F003
611
Acceleration time at a restart
F010
7
Acceleration time
F011
8
Deceleration time
Second acceleration/
F020
44
deceleration time
F021
45
Second deceleration time
Acceleration/deceleration
F100
29
pattern selection
F101
59
Remote function selection
F102
13
Starting frequency
Refer
Name
to page
85
85
85
87
87
88
88
88
159
89
90
90
92
92
acceleration/deceleration
Refer
Name
to page
93
108
159
93
93
93
93
95
96
99
 D: Parameters for the setting of
operation command and
frequency command
Parameters for setting the command source to the inverter,
and the motor driving frequency and torque.
Pr.
Pr.
group
D000
79
Operation mode selection
Communication startup mode
D001
340
selection
Communication operation
D010
338
command source
Communication speed
D011
339
command source
PU mode operation command
D013
551
source selection
Reverse rotation prevention
D020
78
selection
D200
15
Jog frequency
Multi-speed setting (high
D301
4
speed)
Multi-speed setting (middle
D302
5
speed)
Multi-speed setting (low
D303
6
speed)
D304 to
Multi-speed setting (speed 4 to
24 to 27
D307
speed 7)
D308 to
232 to
Multi-speed setting (speed 8 to
D315
239
speed 15)
 H: Protective function parameter
Parameters to protect the motor and the inverter.
Pr.
Pr.
group
Electronic thermal
H000
9
O/L relay
Earth (ground) fault detection
H101
249
at start
Inverter output fault detection
H104
631
enable/disable selection
Undervoltage detection
H105
598
enable/disable selection
Output phase loss protection
H200
251
selection
Input phase loss protection
H201
872
selection
H300
65
Retry selection
Number of retries at fault
H301
67
occurrence
H302
68
Retry waiting time
H303
69
Retry count display erase
H400
1
Maximum frequency
H401
2
Minimum frequency
High speed maximum
H402
18
frequency
H420
31
Frequency jump 1A
H421
32
Frequency jump 1B
Refer
Name
to page
100,
104
104
105
105
105
108
108
109
109
109
109
109
Refer
Name
to page
112,
147
114
114
115
115
115
115
115
115
115
117
117
117
118
118
81