Mitsubishi Electric FR-CS82S-025 Instruction Manual page 131

Hide thumbs Also See for FR-CS82S-025:
Table of Contents

Advertisement

• If the inverter output during inverter running remains higher than the
Output current detection (Y12) signal is output from the inverter's open collector or the relay output terminal.
• Setting
= "1" while the Y12 signal is ON does not cause the fault E.CDO. The
Pr.167
Y12 signal is turned OFF.
• For the Y12 signal, set "12 (positive logic) or 112 (negative logic)" in
the function to the output terminal.
• Use
to select the inverter operation at the time when Y12 signal turns ON, whether to stop the output or to continue
Pr.167
the operation.
Pr.167 setting
0 (initial value)
1
 Pr.167=0
Pr.150
Output current
Output current
detection signal
(Y12)
Parameters referred to
page 147
Offline auto tuning
Pr.195 (Output terminal function selection)
130
5. PARAMETERS
5.7 (M) Item and output signal for monitoring
When the Y12 signal turns ON
Operation continues.
Operation stops by fault (E.CDO).
Pr.151
Time
Pr.167
OFF
OFF
ON
page 126
setting for the time set in
Pr.150
setting becomes valid after the
Pr.167
Pr.195 (Output terminal function selection)
or longer, the
Pr.151
to assign