Mitsubishi Electric FR-CS82S-025 Instruction Manual page 156

Hide thumbs Also See for FR-CS82S-025:
Table of Contents

Advertisement

 Connection diagram
• Sink logic
= "20"
Pr.128
= "99"
Pr.195
*1
Prepare a power supply matched to the power supply specifications of the detector.
*2
The output signal terminal to be used differs according to the Pr.195 (Output terminal function selection) setting.
*3
The input signal terminal to be used differs according to the Pr.178 to Pr.182 (Input terminal function selection) setting.
*4
There is no need to input AU signal.
 Input/output signals
• Assigning the PID control valid (X14) signal to the input terminal by
enables PID control to be performed only when the X14 signal is turned ON. When the X14 signal is OFF, regular inverter
running is performed without PID action .
• Input signal
Signal
Function
X14
PID control valid
• Output signal
Signal
Function
FUP
PID upper limit
FDN
Lower limit output
PID forward/reverse
RL
rotation output
During PID control
PID
activated
SLEEP
PID output interruption
NOTE
• Changing the terminal functions with Pr.178 to Pr.182 or Pr.195 may affect other functions. Set parameters after confirming
the function of each terminal.
MCCB
R/L1
Power supply
S/L2
T/L3
Forward
STF
rotation
Reverse
STR
rotation
PID control
RH(X14)
selection
SD
10
Setting
Potentiometer
2
(Set point setting)
5
4
*4
0 24V
Power
supply
AC1φ
200/220V 50/60Hz
Pr.178 to
Pr.182
setting
When this signal is assigned to the input terminal, PID control is enabled when this
14
signal is ON.
Pr.195 setting
Positive
Negative
logic
logic
15
115
Output when the measured value signal exceeds Pr.131 PID upper limit.
14
114
Output when the measured value signal falls below Pr.132 PID lower limit.
"Hi" is output when the output display of the parameter unit is forward
16
116
rotation (FWD) and "Low" is output when the display is reverse rotation
(REV) and stop (STOP).
47
147
Turns ON during PID control.
Set Pr.575 Output interruption detection time ≠ "9999". This signal turns
70
170
ON when the PID output suspension function is activated.
Inverter
Motor
U
V
M
W
*3
(PID)ABC
During PID action
*2
Upper limit
(FUP)ABC
*2
(FDN)ABC
Lower limit
*2
(Measured value) 4 to 20mA
*1
Pr.178 to Pr.182 (Input terminal function selection)
Description
Description
Pump
P
2-wire type
3-wire type
Detector
(24V)
(OUT)
(COM)
5. PARAMETERS
5.10 (A) Application parameters
2
2
3
4
5
6
7
8
9
10
155