1.3.5 Reinstallation and removal of the control panel

To ensure safety, reinstall and removal the optional control panel (FR-PA02-
switching power off.
The charging area and control printed board are exposed on the rear surface of the
control panel. When removing the control panel, always fit the rear cover option
FR-E5P. Never touch the control printed board because touching it can cause the
inverter to fail.
" " " " Reinstallation of the control panel
Insert the mounting catch (left hand side) of the control panel into the
mounting position of the inverter and push in the right hand side mounting
catch to install the control panel.
1)
" " " " Removal of the control panel
Hold down the portion A indicated by the arrow and lift the right hand side
using the portion B indicated by the arrow as a support, and pull out the
control panel to the right.
1)
(If the above procedure is not used for removal, the internal connector may be
damaged by the force applied.)